A Pilot Study of a Finger Kinematic Parameter-Based Tool for Evaluating Degenerative Cervical Myelopathy
- 11 December 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 49 (5) , 321-331
Abstract
Study Design.: This is a cross-sectional study. Objective.: To evaluate the effectiveness of a novel finger Kinematic Parameter-Based Tool in the grip and release (G&R) test for assessing degenerative cervical myelopathy (DCM). Summary of Background Data.: The development and progression of DCM symptoms are gradual and obscure. Although previous studies have objectively evaluated hand movements specific to myelopathy using the G&R test, virtual reality, or wearable sensors, these methods have limitations, such as limited discrimination or inconvenience for simple screening. Consequently, there is a need to develop effective screening methods. Materials and Methods.: Totally, 297 asymptomatic volunteers and 258 DCM patients were enrolled. This system comprises a wearable acceleration/gyro sensor. The acceleration/gyro sensor was placed on the little finger of the participants to perform 40 cycles of full-range G&R as quickly as possible. The collected data were then transformed into kinematic parameters using sensor-based software and R studio software (version: RStudio 2022.07.2+576, Boston, USA). Gender, age, and body mass index (BMI) subgroups (classified as BMIU test was used for diagnosing the differences between the two groups, and Kruskal-Wallis’s test followed by the Mann-Whitney U test was used for analyzing the differences among three different age groups (60 yr group). The cut-off value of 10s G&R cycles and a combined parameter were determined using receiver operating characteristics curve analysis, area under the curve, and Youden index. Results.: The authors found that little finger kinematic parameters were significantly lower in DCM patients than in asymptomatic participants. The optimal diagnostic indicator appeared to be the average of the top 10 linear accelerations with an area under the curve of 0.923. Conclusion.: The Finger Kinematic Test System is an objective, practical, and quantitative utility that appears to have the capacity to diagnose and evaluate the severity of DCM. Level of Evidence.: 3.Keywords
This publication has 45 references indexed in Scilit:
- Can Elderly Patients Recover Adequately After Laminoplasty? A Comparative Study of 520 Patients With Cervical Spondylotic MyelopathySpine, 2012
- Design and evaluation of a low-cost instrumented glove for hand function assessmentJournal of NeuroEngineering and Rehabilitation, 2012
- Expansive open‐door laminoplasty and selective anterior cervical decompression and fusion for treatment of multilevel cervical spondylotic myelopathyOrthopaedic Surgery, 2011
- Validity of the 10-s step test: prospective study comparing it with the 10-s grip and release test and the 30-m walking testEuropean Spine Journal, 2011
- Myelopathy HandSpine, 2010
- A simple performance test for quantifying the severity of cervical myelopathyThe Journal of Bone and Joint Surgery. British volume, 2008
- Motion analysis of grip and release with fingers using simple magnetic detection systemReview of Scientific Instruments, 2007
- Evaluation of Impairment of Hand Function in Patients With Cervical MyelopathyJournal of Spinal Disorders & Techniques, 2006
- Distal-Type Cervical Spondylotic AmyotrophySpine, 2004
- Hand wasting in spondylotic high cord compression: An electromyographic studyAnnals of Neurology, 1981