Regional anisotropy of airspace orientation in the lung as assessed with hyperpolarized helium‐3 diffusion MRI
- 26 May 2015
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (6) , 1777-1782
Abstract
Purpose To evaluate regional anisotropy of lung‐airspace orientation by assessing the dependence of helium‐3 (3He) apparent diffusion coefficient (ADC) values on the direction of diffusion sensitization at two field strengths. Materials and Methods Hyperpolarized 3He diffusion‐weighted magnetic resonance imaging (MRI) of the lung was performed at 0.43T and 1.5T in 12 healthy volunteers. A gradient‐echo pulse sequence was used with a bipolar diffusion‐sensitization gradient applied separately along three orthogonal directions. ADC maps, median ADC values, and signal‐to‐noise ratios were calculated from the diffusion‐weighted images. Two readers scored the ADC maps for increased values at lung margins, major fissures, or within focal central regions. Results ADC values were found to depend on the direction of diffusion sensitization (P < 0.01, except for craniocaudal vs. anteroposterior directions at 1.5T) and were increased at the lateral and medial surfaces for left‐right diffusion sensitization (12 of 12 subjects); at the apex and base (9 of 12), and along the major fissure (8 of 12), for craniocaudal diffusion sensitization; and at the most anterior and posterior lung (10 of 12) for anteroposterior diffusion sensitization. Median ADC values at 0.43T (0.201 ± 0.017, left‐right; 0.193 ± 0.019, craniocaudal; and 0.187 ± 0.017 cm2/s, anteroposterior) were slightly lower than those at 1.5T (0.205 ± 0.017, 0.197 ± 0.017 and 0.194 ± 0.016 cm2/s, respectively; P < 0.05). Conclusion These findings indicate that diffusion‐weighted hyperpolarized 3He MRI can detect regional anisotropy of lung‐airspace orientation, including that associated with preferential orientation of terminal airways near pleural surfaces. J. MAGN. RESON. IMAGING 2015;42:1777–1782.Keywords
Funding Information
- National Heart, Lung, and Blood Institute of the National Institutes of Health (R01 HL079077)
This publication has 13 references indexed in Scilit:
- Hyperpolarized3He and129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary DiseaseRadiology, 2012
- The influence of field strength on the apparent diffusion coefficient of 3He gas in human lungsMagnetic Resonance in Medicine, 2011
- 3He lung morphometry technique: Accuracy analysis and pulse sequence optimizationJournal of Magnetic Resonance, 2010
- Diffusion‐weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary diseaseMagnetic Resonance in Medicine, 2010
- Quantification of lung microstructure with hyperpolarized 3He diffusion MRIJournal of Applied Physiology, 2009
- Assessment of lung development using hyperpolarized helium‐3 diffusion MR imagingJournal of Magnetic Resonance Imaging, 2006
- MRI of helium‐3 gas in healthy lungs: Posture related variations of alveolar sizeJournal of Magnetic Resonance Imaging, 2004
- Rapid hyperpolarized 3He diffusion MRI of healthy and emphysematous human lungs using an optimized interleaved‐spiral pulse sequenceJournal of Magnetic Resonance Imaging, 2003
- MR imaging of diffusion of3He gas in healthy and diseased lungsMagnetic Resonance in Medicine, 2000
- Relations among alveolar surface tension, surface area, volume, and recoil pressureJournal of Applied Physiology, 1987