A low power respiratory sound diagnosis processing unit based on LSTM for wearable health monitoring
- 21 April 2023
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 68 (5) , 469-480
Abstract
Early prevention and detection of respiratory disease have attracted extensive attention due to the significant increase in people with respiratory issues. Restraining the spread and relieving the symptom of this disease is essential. However, the traditional auscultation technique demands a high-level medical skill, and computational respiratory sound analysis approaches have limits in constrained locations. A wearable auscultation device is required to real-time monitor respiratory system health and provides consumers with ease. In this work, we developed a Respiratory Sound Diagnosis Processor Unit (RSDPU) based on Long Short-Term Memory (LSTM). The experiments and analyses were conducted on feature extraction and abnormality diagnosis algorithm of respiratory sound, and Dynamic Normalization Mapping (DNM) was proposed to better utilize quantization bits and lessen overfitting. Furthermore, we developed the hardware implementation of RSDPU including a corrector to filter diagnosis noise. We presented the FPGA prototyping verification and layout of the RSDPU for power and area evaluation. Experimental results demonstrated that RSDPU achieved an abnormality diagnosis accuracy of 81.4 %, an area of 1.57 × 1.76 mm under the SMIC 130 nm process, and power consumption of 381.8 μW, which met the requirements of high accuracy, low power consumption, and small area.Keywords
Funding Information
- Key Research Program of the Chinese Academy of Sciences (NO. XDPB22)
- Chinese Academy of Sciences (Unassigned)
This publication has 34 references indexed in Scilit:
- Classification of lung sounds using convolutional neural networksEURASIP Journal on Image and Video Processing, 2017
- Automatic adventitious respiratory sound analysis: A systematic reviewPLOS ONE, 2017
- 14.7 A 288µW programmable deep-learning processor with 270KB on-chip weight storage using non-uniform memory hierarchy for mobile intelligence2017
- Integrated real time bowel sound detector for artificial pancreas systemsSensing and Bio-Sensing Research, 2016
- Auscultation of the respiratory systemAnnals of Thoracic Medicine, 2015
- The global burden of respiratory disease-Impact on child healthPediatric Pulmonology, 2014
- An FPGA-Based Rapid Wheezing Detection SystemInternational Journal of Environmental Research and Public Health, 2014
- Asthma and Chronic Obstructive Pulmonary Disease (Copd) and #8211; Differences and SimilaritiesMateria Socio Medica, 2012
- Cardiac Auscultation: Rediscovering the Lost ArtCurrent Problems in Cardiology, 2008
- Does this patient have an abnormal systolic murmur?JAMA, 1997