Correction of analytical results for recovery: a comparison of the method performance characteristics from recent collaborative trials studies for aflatoxin quantification using conventional and robust statistics
Authors:
- 1 August 2002
- journal article
- research article
- Published by Taylor & Francis in Food Additives & Contaminants
- Vol. 19 (8) , 701-708
Abstract
Results from recently conducted collaborative trials on the determination of aflatoxin B1 in various matrices have been evaluated to establish whether the use of recovery data would result in a distinct change of the relative between-laboratory standard deviation (RSDR) of the corrected data compared with the uncorrected data. In addition, we applied conventional and robust statistics to evaluate whether the impact of the use of recovery data on the estimation of RSDR depended on the statistical method applied for data analysis. This investigation was based on means before and after correction for recovery. The method performance characteristics were calculated using results from naturally contaminated test materials, while the results from test materials fortified with the target analytes were used to estimate the recovery. The study revealed that applying conventional and robust statistics in general led to comparable estimates for RSDR. The comparison about the use of recovery data showed that in most cases, the RSDR obtained from the analysis of aflatoxin B1 decreased after correction of the results for recovery. This tendency was similar when the comparison was done using robust or conventional statistics. However, in three cases, conventional statistics yielded a higher RSDR for the corrected data, whereas robust statistics showed the opposite. Looking carefully at the data, the treatment of conventional statistics indicated that the way outliers are detected and removed could result in an under- or overestimation of RSDR. Applying the law of error propagation revealed that most likely the correlation between the uncorrected data and the recovery rate led to a reduced variability of the data corrected for recovery.Keywords
This publication has 9 references indexed in Scilit:
- Determination of Aflatoxin B1 in Baby Food (Infant Formula) by Immunoaffinity Column Cleanup Liquid Chromatography with Postcolumn Bromination: Collaborative StudyJournal of AOAC INTERNATIONAL, 2001
- Examination of Proficiency and Control Recovery Data from Analyses for Pesticide Residues in Food: Sources of VariabilityJournal of AOAC INTERNATIONAL, 2001
- Immunoaffinity Column Cleanup with Liquid Chromatography Using Post-Column Bromination for Determination of Aflatoxins in Peanut Butter, Pistachio Paste, Fig Paste, and Paprika Powder: Collaborative StudyJournal of AOAC INTERNATIONAL, 2000
- Harmonized guidelines for the use of recovery information in analytical measurementPure and Applied Chemistry, 1999
- Measurement uncertainty: Approaches to the evaluation of uncertainties associated with recovery†The Analyst, 1999
- Statistical aspects of proficiency testing in analytical laboratories. Part 3. Confirmatory statistical tests for scheme organisersThe Analyst, 1996
- Protocol for the design, conduct and interpretation of method-performance studies: Revised 1994 (Technical Report)Pure and Applied Chemistry, 1995
- Efficacy of robust analysis of variance for the interpretation of data from collaborative trialsThe Analyst, 1993
- Robust statistics–how not to reject outliers. Part 1. Basic conceptsThe Analyst, 1989