Aims The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation. Materials and Methods Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up. Results A total of 40 studies were analysed: three were Group I and included 80 implants and 37 were Group II and included 1192 implants. In Group I, the mean time to re-operation was 1.37 years (0 to 11.25), the standard minimum follow-up was 3.25 years; painful loosening was the main indication for re-operation. In Group II, 33 Group II articles (89.2%) reported a minimum follow-up of < 3.25 years. Conclusion The literature does not provide a reliable estimate of the rate of re-operation after RHA. The reproducibility of results would be improved by using a minimum follow-up of three years combined with a consensus of the definition of the reasons for failure after RHA. Cite this article: Bone Joint J 2017;99-B:1561–70.Keywords
This publication has 86 references indexed in Scilit:
- Proximal radial drift following radial head resectionJournal of Shoulder and Elbow Surgery, 2011
- Is a Silastic Radial Head Still a Reasonable Option?Clinical Orthopaedics and Related Research, 2011
- Radiocapitellar stability: the effect of soft tissue integrity on bipolar versus monopolar radial head prosthesesJournal of Shoulder and Elbow Surgery, 2011
- Resection arthroplasty for radial head fractures: Long-term follow-upJournal of Shoulder and Elbow Surgery, 2011
- Comparison between radial head replacement and open reduction and internal fixation in clinical treatment of unstable, multi-fragmented radial head fracturesInternational Orthopaedics, 2010
- Comminuted Radial Head Fractures Treated with Pyrocarbon Prosthetic ReplacementHAND, 2010
- The epidemiology of radial head fracturesJournal of Shoulder and Elbow Surgery, 2010
- Radiolucencies surrounding a smooth-stemmed radial head component may not correlate with forearm pain or poor elbow functionJournal of Shoulder and Elbow Surgery, 2009
- Loss of flexion after radial head replacementJournal of Shoulder and Elbow Surgery, 2004
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986