High temporal resolution SSFP cine MRI for estimation of left ventricular diastolic parameters
Open Access
- 29 March 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (4) , 872-880
Abstract
Purpose: To obtain high temporal resolution (HTR) magnetic resonance (MR) steady‐state free‐precession (SSFP) cine cardiac images by using multichannel radiofrequency (RF) hardware and parallel imaging techniques; to study the effect of temporal resolution; and to compare the derived left ventricular (LV) diastolic filling parameters with echocardiographic results.Materials and Methods: HTR images were acquired in 13 healthy volunteers using a 1.5 T scanner with 32 RF channels and sensitivity encoding (SENSE) and k‐t broad‐use linear‐acquisition speedup technique (k‐t BLAST) imaging techniques. LV diastolic parameters were calculated and compared to conventional echocardiographic indices such as the isovolumic relaxation time (IVRT) and E/A ratio. The need for HTR was assessed and the MR results were compared with echocardiographic results.Results: The HTR (≈6‐ms) images yielded higher peak filling rates, peak ejection rates, and peak atrial filling rates. A progressive decline in filling and ejection rates was observed with worsening temporal resolution. The IVRTs and E/A ratios measured with MR versus echocardiography were in broad agreement. Also, SENSE and k‐t BLAST yielded similar diastolic functional parameters.Conclusion: With SENSE or k‐t BLAST and modern hardware, HTR cine images can be obtained. The lower temporal resolutions (30–50 ms) used in clinical practice reduce LV filling rates by ≤30% and may hinder characterization of transient phenomena such as the IVRT. J. Magn. Reson. Imaging 2010;31:872–880. ©2010 Wiley‐Liss, Inc.Keywords
This publication has 35 references indexed in Scilit:
- Prevalence of ventricular diastolic dysfunction in asymptomatic, normotensive patients with diabetes mellitusThe American Journal of Cardiology, 2004
- Association of severe coronary stenosis with subclinical left ventricular dysfunction in the absence of infarctionJournal of the American Society of Echocardiography, 2003
- Coronary flow reserve and myocardial diastolic dysfunction in arterial hypertensionThe American Journal of Cardiology, 2002
- Prevalence of left ventricular diastolic dysfunction by Doppler echocardiography: Clinical application of the Canadian consensus guidelinesJournal of the American Society of Echocardiography, 2002
- New Concepts in Diastolic Dysfunction and Diastolic Heart Failure: Part ICirculation, 2002
- Left ventricular diastolic function assessed using Doppler tissue imaging in patients with hypertrophic cardiomyopathy: relation to symptoms and exercise capacityHeart, 2002
- New Doppler Echocardiographic Applications for the Evaluation of Early Alterations in Left Ventricular Diastolic Function After Coronary AngioplastyEuropean Heart Journal - Cardiovascular Imaging, 2000
- New Doppler echocardiographic applications for the study of diastolic functionJACC, 1998
- Echocardiographic Doppler evaluation of left ventricular diastolic function. Physics and physiology.Circulation, 1991
- Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography.Circulation, 1981