Blood pressure measurement in pregnancy: the effect of arm circumference and sphygmomanometer cuff size
Authors:
- 1 September 2009
- journal article
- research article
- Published by SAGE Publications in Obstetric Medicine
- Vol. 2 (3) , 116-120
Abstract
This study aimed to assess the difference in blood pressure readings between the standard and large cuff and to determine if such a difference applies over a range of arm circumferences (ACs) in pregnancy. We measured blood pressure on 219 antenatal women. Six blood pressure readings were taken, three with a standard ‘adult’ and three with a ‘large’ cuff, in random order. A random zero sphygmomanometer was used by a trained observer. Women with an AC >33 cm were similar in age, gestational age and parity but were heavier and had more hypertension than those with AC ≤33 cm. There was a systematic difference between the standard and large cuff of 5–7 mmHg with little effect due to AC. We were unable to demonstrate an association between the standard and large cuff blood pressure difference and increasing blood pressure. Our study has shown that both systolic and diastolic blood pressure measurements are more dependent on the cuff size used than AC and for the individual it is difficult to predict the magnitude of effect the different cuff sizes will have on blood pressure measurements. This study has shown the presence of an average difference in blood pressure measurement between standard and large cuffs in pregnancy, and does not support the arbitrary 33 cm ‘cut-off’ recommended in guidelines for the use of a large cuff in pregnancy.Keywords
This publication has 28 references indexed in Scilit:
- THE CLASSIFICATION AND DIAGNOSIS OF THE HYPERTENSIVE DISORDERS OF PREGNANCY: STATEMENT FROM THE INTERNATIONAL SOCIETY FOR THE STUDY OF HYPERTENSION IN PREGNANCY (ISSHP)Hypertension in Pregnancy, 2001
- Inaccuracy of the Hawksley random zero sphygmomanometerThe Lancet, 1990
- Blood pressure measurement in adults: large cuffs for all?Journal of Epidemiology and Community Health, 1990
- Blood pressure measurement in the lateral positionBJOG: An International Journal of Obstetrics & Gynaecology, 1989
- A comparison of the random-zero and standard mercury sphygmomanometers.Hypertension, 1988
- Accuracy of auscultatory blood pressure measurement with a long cuff.BMJ, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The error in indirect blood pressure measurement with the incorrect size of cuffAmerican Heart Journal, 1978
- THE ACCURACY OF AUSCULTATORY MEASUREMENT OF ARM BLOOD PRESSURE IN VERY OBESE SUBJECTSActa Medica Scandinavica, 1974
- Effect of size of cuff bladder on accuracy of measurement of indirect blood pressureAmerican Heart Journal, 1965