Temporal Relationship of Implantable Cardioverter Defibrillator Discharges and Environmental Physical Activity
- 1 August 2005
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (8) , 777-781
Abstract
Studies by our group have shown an inverse relationship between sudden death and cardiac rhythm disturbances and environmental levels of geomagnetic activity (GMA). The aim of this study was to use the precise data provided by automatic implantable cardioverter defibrillators (ICDs) regarding the onset of ventricular fibrillation and ventricular tachycardia to link these events to GMA level. The study group included 25 patients (22 men; 22 with ischemic cardiomyopathy) aged 28-81 years in whom an ICD had been implanted between 1995 and 2004. Patients were referred to the cardiac intensive care unit after each event that induced one or more discharges. The number of events and the day on which they occurred were recorded. Data on GMA and other cosmophysical parameters were obtained from the U.S. National Geophysical and Space Service Centers and the Russian Academy of Sciences. GMA levels, graded from I (quiet) to IV (stormy) in the middle latitutes, were recorded for 1974-2003 (10,954 days) and for each day on which an ICD discharge occurred. A total of 402 discharges were recorded on 137 days during the study period. Forty-six percent of the discharges took place on days of GMA I, compared with 38% - II, 13% - III, and 3% - IV. The daily distribution of GMA was as follows: level I - 35.2%, II - 37.3%, III - 21.86%, IV - 5.61%. Comparison of ICD discharge days and actual multiyear levels of GMA (in percent) yielded a ratio of 1.326 for GMA I, 1.076 - II, 0.459 - III, 0.390 - IV. There was a significant inverse correlation between GMA level and number of discharges (r =-0.97, P = 0.03) and days of treatment (r =-0.96, P = 0.039), and a significant difference between ICD discharges on days of GMA I and GMA II-IV (chi(2)= 5.05, P = 0.02). The higher number of ICD discharges on days of lowest GMA may be explained by a possible antiarrhythmic effect of GMA. Environmental arrhythmogenic factors that act inversely to GMA may be activated at times of low GMA.Keywords
This publication has 13 references indexed in Scilit:
- Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated CardiomyopathyNew England Journal of Medicine, 2004
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureThe New England journal of medicine, 2004
- Life-Years Gained From Defibrillator ImplantationCirculation, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionThe New England journal of medicine, 2002
- Efficacy of Implantable Cardioverter–Defibrillators for the Prevention of Sudden Death in Patients with Hypertrophic CardiomyopathyNew England Journal of Medicine, 2000
- A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1999
- PAROXYSMAL ATRIAL FIBRILLATION AND STROKE (CEREBROVASCULAR ACCIDENTS) IN MALES AND FEMALES ABOVE AND BELOW AGE 65 ON DAYS OF DIFFERENT GEOMAGNETIC ACTIVITY LEVELSJournal of Basic and Clinical Physiology and Pharmacology, 1994
- SUDDEN CARDIAC DEATHS AND VENTRICULAR EXTRASYSTOLES ON DAYS WITH FOUR LEVELS OF GEOMAGNETIC ACTIVITYJournal of Basic and Clinical Physiology and Pharmacology, 1993
- Standby automatic defibrillator. An approach to prevention of sudden coronary deathArchives of internal medicine (1960), 1970
- Electrical reversion of cardiac arrhythmias.Heart, 1967