Controlling retention, selectivity and magnitude of EOF by segmented monolithic columns consisting of octadecyl and naphthyl monolithic segments – applications to RP‐CEC of both neutral and charged solutes
Authors:
- 31 March 2011
- journal article
- ce and-cec
- Published by Wiley in Electrophoresis
- Vol. 32 (9) , 1033-1043
Abstract
Monolithic capillaries made of two adjoining segments each filled with a different monolith were introduced for the control and manipulation of the electroosmotic flow (EOF), retention and selectivity in reversed phase‐capillary electrochromatography (RP‐CEC). These columns were called segmented monolithic columns (SMCs) where one segment was filled with a naphthyl methacrylate monolith (NMM) to provide hydrophobic and π‐interactions, while the other segment was filled with an octadecyl acrylate monolith (ODM) to provide solely hydrophobic interaction. The ODM segment not only provided hydrophobic interactions but also functioned as the EOF accelerator segment. The average EOF of the SMC increased linearly with increasing the fractional length of the ODM segment. The neutral SMC provided a convenient way for tuning EOF, selectivity and retention in the absence of annoying electrostatic interactions and irreversible solute adsorption. The SMCs allowed the separation of a wide range of neutral solutes including polycyclic aromatic hydrocarbons (PAHs) that are difficult to separate using conventional alkyl‐bonded stationary phases. In all cases, the k′ of a given solute was a linear function of the fractional length of the ODM or NMM segment in the SMCs, thus facilitating the tailoring of a given SMC to solve a given separation problem. At some ODM fractional length, the fabricated SMC allowed the separation of charged solutes such as peptides and proteins that could not otherwise be achieved on a monolithic column made from NMM as an isotropic stationary phase due to the lower EOF exhibited by this monolith.Keywords
This publication has 24 references indexed in Scilit:
- Naphthyl methacrylate‐based monolithic column for RP‐CEC via hydrophobic and π interactionsElectrophoresis, 2010
- Electrophoretic and electrochromatographic separation of proteins in capillaries: An update covering 2007–2009Electrophoresis, 2009
- Neutral octadecyl monolith for reversed phase capillary electrochromatography of a wide range of solutesJournal of Separation Science, 2008
- Two-Dimensional Microcolumn Separation Platform for Proteomics Consisting of On-Line Coupled Capillary Isoelectric Focusing and Capillary Electrochromatography. 1. Evaluation of the Capillary-Based Two-Dimensional Platform with Proteins, Peptides, and Human SerumJournal of Proteome Research, 2006
- Capillary electrochromatography with monolithic stationary phases. 4. Preparation of neutral stearyl - acrylate monoliths and their evaluation in capillary electrochromatography of neutral and charged small species as well as peptides and proteinsElectrophoresis, 2005
- Capillary electrochromatography with monolithic stationary phasesJournal of Chromatography A, 2003
- Capillary electrochromatography with monolithic stationary phasesJournal of Chromatography A, 2003
- Coupled fused silica capillaries for rapid capillary zone electrophoresis of proteinsJournal of High Resolution Chromatography, 1992
- Tandem columns and mixed-bed columns in high-performance liquid chromatography of proteinsJournal of Chromatography A, 1986
- Adjustment of stationary phase selectivity in gas—liquid chromatography by using mixed liquid phasesJournal of Chromatography A, 1978