Accuracy of Continuous Noninvasive Hemoglobin Monitoring
Authors:
- Marc LilotMLMarc Lilot
- Linda Suk-Ling MurphyLMLinda Suk-Ling Murphy
- Kulraj S. SidhuKSKulraj S. Sidhu
- Zhaoxia YuZYZhaoxia Yu
- Joseph RinehartJRJoseph Rinehart
- Maxime CannessonMCMaxime Cannesson
- 1 August 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 119 (2) , 332-346
Abstract
Noninvasive hemoglobin (Hb) monitoring devices are available in the clinical setting, but their accuracy and precision against central laboratory Hb measurements have not been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the literature (2005 to August 2013) with PubMed, Web of Science and the Cochrane Library, reviewed references of retrieved articles, and contacted manufactures to identify studies assessing the accuracy of noninvasive Hb monitoring against central laboratory Hb measurements. Two independent reviewers assessed the quality of studies using recommendations for reporting guidelines and quality criteria for method comparison studies. Pooled mean difference and standard deviation (SD) (95% limits of agreement) across studies were calculated using the random-effects model. Heterogeneity was assessed using the I2 statistic. A total of 32 studies (4425 subjects, median sample size of 44, ranged from 10 to 569 patients per study) were included in this meta-analysis. The overall pooled random-effects mean difference (noninvasive—central laboratory) and SD were 0.10 ± 1.37 g/dL (−2.59 to 2.80 g/dL, I2 = 95.9% for mean difference and 95.0% for SD). In subgroup analysis, pooled mean difference and SD were 0.39 ± 1.32 g/dL (−2.21 to 2.98 g/dL, I2 = 93.0%, 71.4%) in 13 studies conducted in the perioperative setting and were −0.51 ± 1.59 g/dL (−3.63 to 2.62 g/dL, I2 = 83.7%, 96.4%) in 5 studies performed in the intensive care unit setting. Although the mean difference between noninvasive Hb and central laboratory measurements was small, the wide limits of agreement mean clinicians should be cautious when making clinical decisions based on these devices.Keywords
This publication has 53 references indexed in Scilit:
- Comparison of the Accuracy of Noninvasive Hemoglobin Sensor (NBM-200) and Portable Hemoglobinometer (HemoCue) with an Automated Hematology Analyzer (LH500) in Blood Donor ScreeningAnnals of Laboratory Medicine, 2013
- Accuracy of the Masimo Pronto-7® system in patients with left ventricular assist deviceJournal of Cardiothoracic Surgery, 2013
- Accuracy of Noninvasive and Invasive Point-of-Care Total Blood Hemoglobin Measurement in an Outpatient SettingPostgraduate Medicine, 2012
- Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, SudanDiagnostic Pathology, 2012
- Non-Invasive Measurement of Hemoglobin: Assessment of Two Different Point-of-Care TechnologiesPLOS ONE, 2012
- Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin MeasurementAnesthesiology, 2011
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Measuring inconsistency in meta-analysesBMJ, 2003
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986