Evaluation of the effectiveness of a tunnel-shaped radiation shielding system in CT-guided interventions: Reduction of scattered radiation in phantom experiment
- 6 November 2025
- journal article
- Published by SAGE Publications in Acta Radiologica
- Vol. 67 (1) , 85-95
Abstract
Background: Computed tomography (CT) fluoroscopy provides high-resolution images and is widely used for safe and accurate procedures, but it exposes operators to high radiation doses. Purpose: To develop and evaluate a tunnel-shaped shielding system to reduce operator exposure to scattered radiation during CT fluoroscopy-guided procedures. Material and Methods: The shield, designed based on scattered radiation distribution, consists of a semi-cylindrical leaded acrylic part and a bottom plate with a non-lead shielding board surrounding the patient. Radiation doses were measured with and without the shield using patient and operator phantoms. Dosimeters were placed at 10 locations on the operator phantom, including the eye lens, thyroid, chest, abdomen, pelvis, legs, patient-side armpit, and needle-holding hand. Percentage reductions in radiation exposure were calculated. Results: The tunnel-shaped shield significantly reduced radiation exposure, with dose reductions of 83%–100% at the eye lens, 88%–96% at the thyroid, 84%–95% at the upper chest, 84%–92% at the lower chest, 88%–94% at the abdomen, 91%–94% at the pelvis, 57%–68% at the upper leg, 44%–83% at the lower leg, 90%–94% at the patient-side armpit, and 73%–86% at the needle-holding hand. All reductions were statistically significant. Conclusion: Phantom experiments demonstrated that the tunnel-shaped shielding system effectively reduces operator exposure to scattered radiation during CT fluoroscopy-guided procedures.Keywords
Funding Information
- JSPS KAKENHI (JP22K12898)
This publication has 9 references indexed in Scilit:
- Effectiveness of Attaching a Lead Drape to a Radioprotective Shield for CT Fluoroscopy–Guided ProceduresJournal of Vascular and Interventional Radiology, 2024
- Occupational Radiation Dose to Eye Lenses in CT-Guided Interventions Using MDCT-FluoroscopyDiagnostics, 2021
- Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional RadiologyJournal of Vascular and Interventional Radiology, 2010
- CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and OperatorJournal of Vascular and Interventional Radiology, 2006
- CT Fluoroscopy-guided Intervention: Marked Reduction of Scattered Radiation Dose to the Physician's Hand by Use of a Lead Plate and an Improved I-I DeviceJournal of Vascular and Interventional Radiology, 2001
- CT Fluoroscopy-guided Interventional Procedures: Techniques and Radiation Dose to RadiologistsRadiology, 2001
- Benefits and Safety of CT Fluoroscopy in Interventional Radiologic ProceduresRadiology, 2001
- Patient and Personnel Exposure during CT Fluoroscopy-guided Interventional ProceduresRadiology, 2000
- Radiation dosimetry at CT fluoroscopy: physician's hand dose and development of needle holders.Radiology, 1996