Interobserver and Intraobserver Reliability of Cephalometric Measurements Performed on Smartphone-Based Application and Computer-Based Imaging Software: A Comparative Study
Open Access
- 22 June 2023
- journal article
- research article
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 36 (2) , 94-100
Abstract
The aim was to compare the reliability of cephalometric analysis using a smartphone-based application with conventional computer-based imaging software. Pre-treatment cephalometric radiographs of 50 subjects (26 males, 24 females; mean age, 19.2 years; ±4.2) were traced using the OneCeph® application and Dolphin imaging software®. Two independent observers identified seventeen landmarks and measured fourteen cephalometric measurements at an interval of. Interobserver and intraobserver reliability were evaluated using the intraclass correlation coefficient. Student's t-test was used to compare the means of two measurement methods for observer 1 and observer 2. Additionally, the time taken to complete the cephalometric measurements was also compared between the two methods. Good (ICC 0.75-0.90) to excellent (ICC 0.90-1.00) interobserver and intraobserver reliability was observed for all hard and soft tissue measurements with both methods. No significant differences were found between the two measurement methods for both observers (p<0.05). OneCeph application took significantly more time to complete the analysis than Dolphin imaging software (p<0.001). Cephalometric measurements made through a smartphone-based application showed good to excellent interobserver and intraobserver reliability and are comparable with the computer-based software. Therefore, it can be recommended for clinical use. The time taken to complete the cephalometric measurements was more with a smartphone-based application (OneCeph application) compared to computer-based software (Dolphin imaging software).Keywords
This publication has 18 references indexed in Scilit:
- Ocular and visual discomfort associated with smartphones, tablets and computers: what we do and do not knowClinical and Experimental Optometry, 2019
- The influences of smartphone use on the status of the tear film and ocular surfacePLOS ONE, 2018
- A Web-based Sample Size Calculator for Reliability StudiesEducation in Medicine Journal, 2018
- Reliability Assessment of Orthodontic Apps for CephalometricsTurkish Journal of Orthodontics, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Efficacy of a Newly Designed Cephalometric Analysis Software for McNamara Analysis in Comparison with Dolphin Software2015
- Reliability of four different computerized cephalometric analysis programsEuropean Journal of Orthodontics, 2011
- Estudo comparativo entre traçados cefalométricos manual e digital, através do programa Dolphin Imaging em telerradiografias lateraisDental Press Journal of Orthodontics, 2010
- Dolphin Imaging Software: An analysis of the accuracy of cephalometric digitization and orthognathic predictionInternational Journal of Oral and Maxillofacial Surgery, 2005
- Statistical Methods for Medical and Biological StudentsBMJ, 1940