Computation of Surface Laplacian for tri-polar ring electrodes on high-density realistic geometry head model
Authors:
- 1 July 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 49 (1557170X) , 3616-3619
Abstract
Neural activity inside the human brain generate electrical signals that can be detected on the scalp. Electroencephalograph (EEG) is one of the most widely utilized techniques helping physicians and researchers to diagnose and understand various brain diseases. Due to its nature, EEG signals have very high temporal resolution but poor spatial resolution. To achieve higher spatial resolution, a novel tri-polar concentric ring electrode (TCRE) has been developed to directly measure Surface Laplacian (SL). The objective of the present study is to accurately calculate SL for TCRE based on a realistic geometry head model. A locally dense mesh was proposed to represent the head surface, where the local dense parts were to match the small structural components in TCRE. Other areas without dense mesh were used for the purpose of reducing computational load. We conducted computer simulations to evaluate the performance of the proposed mesh and evaluated possible numerical errors as compared with a low-density model. Finally, with achieved accuracy, we presented the computed forward lead field of SL for TCRE for the first time in a realistic geometry head model and demonstrated that it has better spatial resolution than computed SL from classic EEG recordings.Keywords
This publication has 12 references indexed in Scilit:
- Issues and considerations for using the scalp surface Laplacian in EEG/ERP research: A tutorial reviewInternational Journal of Psychophysiology, 2015
- High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring ElectrodesIEEE Journal of Translational Engineering in Health and Medicine, 2014
- Lasting Modulation Effects of rTMS on Neural Activity and Connectivity as Revealed by Resting-State EEGIEEE Transactions on Biomedical Engineering, 2014
- Effects of transcranial focal electrical stimulation via tripolar concentric ring electrodes on pentylenetetrazole-induced seizures in ratsEpilepsy Research, 2013
- Brainstorm: A User-Friendly Application for MEG/EEG AnalysisComputational Intelligence and Neuroscience, 2011
- Application of Tripolar Concentric Electrodes and Prefeature Selection Algorithm for Brain–Computer InterfaceIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2008
- Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodesJournal of Neuroscience Methods, 2007
- Tri-polar concentric ring electrode development for Laplacian electroencephalographyIEEE Transactions on Biomedical Engineering, 2006
- Concentric-ring electrode systems for noninvasive detection of single motor unit activityIEEE Transactions on Biomedical Engineering, 2001
- An on-line transformation of EEG scalp potentials into orthogonal source derivationsElectroencephalography and Clinical Neurophysiology, 1975