Inferior colliculus responses to dual-site intralamina stimulation in the ventral cochlear nucleus
- 17 June 2010
- journal article
- research article
- Published by Wiley in Journal of Comparative Neurology
- Vol. 518 (20) , 4226-4242
Abstract
A major limitation of the present auditory brainstem implant (ABI) is its inability to access the tonotopic organization of the ventral cochlear nucleus (VCN). A previous study by our group indicated that stimulation of single sites within a given VCN frequency region did not always elicit frequency-specific responses within the central nucleus of the inferior colliculus (CIC) and in some cases did not elicit a response at all. For this study, we hypothesized that sequential stimulation (with a short interpulse delay of 320 μsec) of two VCN sites in similar frequency regions would enhance responsiveness in CIC neurons. Multiunit neural recordings in response to pure tones were obtained at 58 VCN and 164 CIC sites in anesthetized rats. Among the 58 VCN sites, 39 pairs of sites with similar characteristic frequencies were chosen for electrical stimulation. Each member of a VCN pair was electrically stimulated individually, followed by sequential stimulation of the pair, while recording CIC responses. On average, CIC sites were found to respond to dual-site VCN stimulation with significantly lower thresholds, wider dynamic ranges, a greater extent of activation with increasing current levels, and a higher degree of frequency specificity compared with single-site stimulation. Although these effects were positive for the most part, in some cases dual-site stimulation resulted in increased CIC thresholds and decreased dynamic ranges, extent of activation, and frequency specificity. The results suggest that multisite stimulation within VCN isofrequency laminae using penetrating electrodes could significantly improve ABI stimulation strategies and implant performance. J. Comp. Neurol. 518:4226–4242, 2010.Keywords
This publication has 54 references indexed in Scilit:
- Outcomes in Nontumor Adults Fitted With the Auditory Brainstem ImplantOtology & Neurotology, 2009
- Open Set Speech Perception with Auditory Brainstem Implant?The Laryngoscope, 2005
- Auditory Brainstem Implant (ABI): New Frontiers in Adults and ChildrenOtolaryngology–Head and Neck Surgery, 2005
- Auditory Brainstem Implant in Posttraumatic Cochlear Nerve AvulsionAudiology and Neurotology, 2004
- Cochlear implant failure: is an auditory brainstem implant the answer?Acta Oto-Laryngologica, 2004
- Cortical Responses to Cochlear Implant Stimulation: Channel InteractionsJournal of the Association for Research in Otolaryngology, 2004
- Current management of acoustic neuromas: review of surgical approaches and outcomesJournal of Clinical Neuroscience, 2000
- Surgical Implantation and Biocompatibility of Central Nervous System Auditory ProsthesesAnnals of Otology, Rhinology & Laryngology, 1989
- Batch fabricated thin-film electrodes for stimulation of the central auditory systemIEEE Transactions on Biomedical Engineering, 1989
- Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline (neurological stimulation application)IEEE Transactions on Biomedical Engineering, 1988