Effect of Poly-l-Lysine Polycation on the Glucose Oxidase/Ferricyanide Composite-Based Second-Generation Blood Glucose Sensors
Open Access
Abstract
Second-generation glucose biosensors are presently the mainstream commercial solution for blood glucose measurement of diabetic patients. Screen-printed carbon electrodes (SPCEs) are the most-used substrate for glucose testing strips. This study adopted hydrophilic and positively charged α-poly-l-lysine (αPLL) as the entrapment matrix for the immobilization of negatively charged glucose oxidase (GOx) and ferricyanide (FIC) on SPCEs to construct a disposable second-generation glucose biosensor. The αPLL modification is shown to facilitate the redox kinetics of FIC and ferrocyanide on the SPCEs. The SPCEs coated with 0.5 mM GOx, 99.5 mM FIC, and 5 mM αPLL had better sensitivity for glucose detection due to the appreciable effect of protonated αPLL on the promotion of electron transfer between GOx and FIC. Moreover, the SPCEs coated with 0.5 mM GOx, 99.5 mM FIC, and 5 mM αPLL were packaged as blood glucose testing strips for the measurement of glucose-containing human serum samples. The glucose testing strips had good linearity from 2.8 mM to 27.5 mM and a detection limit of 2.3 mM. Moreover, the 5 mM αPLL-based glucose testing strips had good long-term stability to maintain GOx activity in aging tests at 50 °C.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST107-2321-B-005-014, MOST107-2313-B-005-006-MY3)
- Ministry of Education, Taiwan (Innovation and Development Center of Sustainable Agriculture)
This publication has 47 references indexed in Scilit:
- A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and GrapheneSensors, 2012
- Metamaterials on Paper as a Sensing PlatformAdvanced Materials, 2011
- Electrochemical impedance studies of chitosan-modified electrodes for application in electrochemical sensors and biosensorsElectrochimica Acta, 2010
- Glucose Biosensors: An Overview of Use in Clinical PracticeSensors, 2010
- Superior long-term stability of a glucose biosensor based on inserted barrel plating gold electrodesBiosensors and Bioelectronics, 2009
- The evolution of commercialized glucose sensors in ChinaBiosensors and Bioelectronics, 2009
- A novel amperometric biosensor based on NiO hollow nanospheres for biosensing glucoseTalanta, 2008
- Effects of Electrolyte and pH on the Behavior of Cross-Linked Films of Ferrocene-Modified Poly(ethylenimine)Langmuir, 2007
- A glucose biosensor using methyl viologen redox mediator on carbon film electrodesAnalytica Chimica Acta, 2005
- A glucose sensor fabricated by the screen printing techniqueBiosensors and Bioelectronics, 1995