Harmonic Distortion Assessment and Minimization for Railway Systems
Authors:
- 16 June 2009
- journal article
- research article
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 37 (8) , 832-846
Abstract
This article addresses the power quality issues in railway systems. It starts with a distributed parameter approach to the determination of the current and voltage harmonics along a railway feeder. For the assessment of the harmonic distortion, three global indices for the harmonic voltage, current, and power are suggested, which take into account the spatial harmonic distribution (up to the 19th harmonic) along the entire feeder and the feeder length for all possible locomotive positions. Also, they consider the receiving-end resistance representing the power quality conditioner of the feeder's end. This is followed by a proposed technique for identifying the optimal value of this resistance, resulting in the least values of the proposed global harmonic distortion indices. It is shown that the two resistance values yielding the minima of both voltage and current harmonic indices are almost equal and are larger than the one leading to the least harmonic index for the harmonic power. A comparison of the improved harmonic conditions with the identified optimal feeder termination resistance indicates the applicability of the suggested approach.Keywords
This publication has 5 references indexed in Scilit:
- Simplified Modeling of 2$\,\times\,$25-kV AT Railway System for the Solution of Low Frequency and Large-Scale ProblemsIEEE Transactions on Power Delivery, 2006
- Harmonic Analysis of the Korean High-Speed Railway Using the Eight-Port Representation ModelIEEE Transactions on Power Delivery, 2006
- Optimal Impedance Termination of 25-kV Electrified Railway Systems for Improved Power QualityIEEE Transactions on Power Delivery, 2005
- Voltage form factor control and reactive power compensation in a 25-kV electrified railway system using a shunt active filter based on voltage detectionIEEE Transactions on Industry Applications, 2003
- Considerations of a shunt active filter based on voltage detection for installation on a long distribution feederIEEE Transactions on Industry Applications, 2002