Comparison of periprosthetic tissue digestion methods for ultra‐high molecular weight polyethylene wear debris extraction
- 8 June 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 91B (1) , 409-418
Abstract
There is considerable interest in characterization of wear debris from polyethylene (UHMWPE) bearing components used in total joint replacement. To isolate UHMWPE wear debris, tissue samples must be excised from regions adjacent to revised UHMWPE implant components, followed by exposure to one of many available tissue digestion methods. Numerous studies demonstrate successful digestion, but the relative efficiency of each method is not clear. The purpose of this study was to evaluate a variety of conditions for tissue digestion to provide a quantitative comparison of methods. Porcine and human hip tissues were exposed for 24 h to basic, acidic or enzymatic agents, filtered and digestion efficiency calculated based on the percentage of initial to final tissue weight. Of the conditions tested, 5 M NaOH, 5 M KOH, 15 M KOH or 15.8 M HNO3 yielded the most complete porcine hip tissue digestion (p < 0.05). Proteinase K and Liberase Blendzyme 3 did not effectively digest tissue in a 24 h period. Similar to results from the porcine dataset, human tissues digestion was most efficient using 5 M NaOH, 5 M KOH or 15.8 M HNO3 (p < 0.05). To verify that particle surface modifications did not occur after prolonged reagent exposure, GUR415 and Ceridust 3715 particles were immersed in each solution for 24 h. Overall, this study provides a framework for thorough and efficient digestive methods for UHMWPE wear debris extraction. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009Keywords
This publication has 42 references indexed in Scilit:
- The Central Role of Wear Debris in Periprosthetic OsteolysisHSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2006
- Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulatorsJournal of Biomedical Materials Research Part A, 2006
- Distinct gene expression of receptor activator of nuclear factor-κB and rank ligand in the inflammatory response to variant morphologies of UHMWPE particlesBiomaterials, 2003
- Standardized analysis of UHMWPE wear particles from failed total joint arthroplastiesJournal of Biomedical Materials Research, 2002
- Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacementsJournal of Biomedical Materials Research, 2000
- Human arthroplasty derived macrophages differentiate into osteoclastic bone resorbing cellsAnnals of the Rheumatic Diseases, 1997
- Analysis of polyethylene wear debris using micro-Raman spectroscopy: A report on the presence of beta-caroteneJournal of Biomedical Materials Research, 1997
- Shapes and dimensional characteristics of polyethylene wear particles generatedin vivo by total knee replacements compared to total hip replacementsJournal of Biomedical Materials Research, 1997
- Tissue digestion for wear debris particle isolationJournal of Biomedical Materials Research, 1994
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977