Motion correction for native myocardial T1 mapping using self‐supervised deep learning registration with contrast separation
- 15 June 2022
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (10) , e4775
Abstract
In myocardial T1 mapping, undesirable motion poses significant challenges because uncorrected motion can affect T1 estimation accuracy and cause incorrect diagnosis. In this study, we propose and evaluate a motion correction method for myocardial T1 mapping using self‐supervised deep learning based registration with contrast separation (SDRAP). A sparse coding based method was first proposed to separate the contrast component from T1‐weighted (T1w) images. Then, a self‐supervised deep neural network with cross‐correlation (SDRAP‐CC) or mutual information as the registration similarity measurement was developed to register contrast separated images, after which signal fitting was performed on the motion corrected T1w images to generate motion corrected T1 maps. The registration network was trained and tested in 80 healthy volunteers with images acquired using the modified Look–Locker inversion recovery (MOLLI) sequence. The proposed SDRAP was compared with the free form deformation (FFD) registration method regarding (1) Dice similarity coefficient (DSC) and mean boundary error (MBE) of myocardium contours, (2) T1 value and standard deviation (SD) of T1 fitting, (3) subjective evaluation score for overall image quality and motion artifact level, and (4) computation time. Results showed that SDRAP‐CC achieved the highest DSC of 85.0 ± 3.9% and the lowest MBE of 0.92 ± 0.25 mm among the methods compared. Additionally, SDRAP‐CC performed the best by resulting in lower SD value (28.1 ± 17.6 ms) and higher subjective image quality scores (3.30 ± 0.79 for overall quality and 3.53 ± 0.68 for motion artifact) evaluated by a cardiologist. The proposed SDRAP took only 0.52 s to register one slice of MOLLI images, achieving about sevenfold acceleration over FFD (3.7 s/slice).Keywords
Funding Information
- Natural Science Foundation of Beijing Municipality (Z190024)
- National Natural Science Foundation of China (81, 930, 119)
This publication has 29 references indexed in Scilit:
- Adaptive registration of varying contrast‐weighted images for improved tissue characterization (ARCTIC): Application to T1mappingMagnetic Resonance in Medicine, 2014
- Respiratory motion correction in dynamic MRI using robust data decomposition registration – Application to DCE-MRIMedical Image Analysis, 2014
- Deformable Medical Image Registration: A SurveyIEEE Transactions on Medical Imaging, 2013
- Native T1 Mapping in Differentiation of Normal Myocardium From Diffuse Disease in Hypertrophic and Dilated CardiomyopathyJACC: Cardiovascular Imaging, 2013
- Phase‐sensitive inversion recovery for myocardialT1mapping with motion correction and parametric fittingMagnetic Resonance in Medicine, 2012
- Motion correction for myocardial T1 mapping using image registration with synthetic image estimationMagnetic Resonance in Medicine, 2011
- Optimization and validation of a fully‐integrated pulse sequence for modified look‐locker inversion‐recovery (MOLLI) T1 mapping of the heartJournal of Magnetic Resonance Imaging, 2007
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- Nonrigid registration using free-form deformations: application to breast MR imagesIEEE Transactions on Medical Imaging, 1999
- Emergence of simple-cell receptive field properties by learning a sparse code for natural imagesNature, 1996