Intercomparison of UV-visible measurements of ozone and NO2 during the Canadian Arctic ACE validation campaigns: 2004–2006
Authors:
Open Access
- 26 March 2008
- journal article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 8 (6) , 1763-1788
Abstract
The first three Canadian Arctic ACE validation campaigns were held during polar sunrise at Eureka, Nunavut, Canada (80° N, 86° W) from 2004 to 2006 in support of validation of the ACE (Atmospheric Chemistry Experiment) satellite mission. Three or four zenith-sky viewing UV-visible spectrometers have taken part in each of the three campaigns. The differential slant column densities and vertical column densities of ozone and NO2 from these instruments have been compared following the methods of the UV-visible Working Group of the NDACC (Network for Detection of Atmospheric Composition Change). The instruments are found to partially agree within the required accuracies for both species, although both the vertical and slant column densities are more scattered than required. This might be expected given the spatial and temporal variability of the Arctic stratosphere in spring. The vertical column densities are also compared to integrated total columns from ozonesondes and integrated partial columns from the ACE-FTS (ACE-Fourier Transform Spectrometer) and ACE-MAESTRO (ACE-Measurements of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation) instruments on board ACE. For both species, the columns from the ground-based instruments and the ozonesondes are found to generally agree within their combined error bars. The ACE-FTS ozone partial columns and the ground-based total columns agree within 4.5%, averaged over the three campaigns. The ACE-MAESTRO ozone partial columns are generally smaller than those of the ground-based instruments, by an average of 9.9%, and are smaller than the ACE-FTS columns by an average of 14.4%. The ACE-FTS NO2 partial columns are an average of 13.4% smaller than the total columns from the ground-based instruments, as expected. The ACE-MAESTRO NO2 partial columns are larger than the total columns of the ground-based instruments by an average of 2.5% and are larger than the partial columns of the ACE-FTS by an average of 15.5%.Keywords
All Related Versions
This publication has 33 references indexed in Scilit:
- The high Arctic in extreme winters: vortex, temperature, and MLS and ACE-FTS trace gas evolutionEGUsphere, 2007
- Atmospheric Chemistry Experiment (ACE): Mission overviewGeophysical Research Letters, 2005
- The HITRAN molecular spectroscopic database: edition of 2000 including updates through 2001Journal of Quantitative Spectroscopy and Radiative Transfer, 2003
- Validation of POAM III NO2 measurementsJournal of Geophysical Research: Atmospheres, 2002
- Stratospheric ozone in 3‐D models: A simple chemistry and the cross‐tropopause fluxJournal of Geophysical Research: Atmospheres, 2000
- Measurements of the NO2 absorption cross-section from 42 000 cm−1 to 10 000 cm−1 (238–1000 nm) at 220 K and 294 KJournal of Quantitative Spectroscopy and Radiative Transfer, 1998
- Accuracy of measurements of total ozone by a SAOZ ground‐based zenith sky visible spectrometerJournal of Geophysical Research: Atmospheres, 1997
- A spectroradiometer for the measurement of direct and scattered solar irradiance from on‐board the NASA ER‐2 high‐altitude research aircraftGeophysical Research Letters, 1995
- On the Motion of Air through the Stratospheric Polar VortexJournal of the Atmospheric Sciences, 1994
- O3 and NO2 ground‐based measurements by visible spectrometry during Arctic winter and spring 1988Geophysical Research Letters, 1988