Challenges and Opportunities in ILR Selection for Photovoltaic System: Evaluation in Brazilian Cities
Open Access
Abstract
The sizing of photovoltaic (PV) systems has been a concern since the 1990s, particularly with the trend of inverter undersizing as PV module prices decrease. While many studies have assessed the behavior of AC energy and economic parameters with varying Inverter Load Ratios (ILRs), they often neglect the impact of degradation on system lifetime or fail to analyze how it influences ILR selection in depth. This study examines the relationship between DC loss curves and ILRs, their evolution over time, and their effects on efficiency and Final Yield. Simulating solar resources in 27 Brazilian cities, it evaluates clipping losses and optimal ILR values ranging from 0.8 to 2.0 for 28 recent inverters. The research aims to identify the ILR that minimizes the Levelized Cost of Energy (LCOE) while maximizing Final Yield, revealing variations in optimal ILR ranges across different inverter–city combinations. The optimal ILR was between 1.1 and 1.3 for modern medium- and high-power inverters, while low-power inverters had a range of up to 1.8. The findings highlight that practical ILR considerations can overlook real-world challenges, leaving the system’s full potential untapped.Keywords
All Related Versions
Funding Information
- Ministério da Ciência, Tecnologia e Inovação (MCTI) (403998/2022-0, 07/2022)
- CNPq (403998/2022-0, 07/2022)
This publication has 21 references indexed in Scilit:
- A comparison study of grid impact of photovoltaic installations in Brazil according to Normative Resolution 482 and Federal law 14.300Energy Policy, 2023
- Optimum inverter sizing of grid-connected photovoltaic systems based on energetic and economic considerationsRenewable Energy, 2018
- Mathematical models for efficiency of inverters used in grid connected photovoltaic systemsRenewable and Sustainable Energy Reviews, 2014
- MPPT techniques for photovoltaic applicationsRenewable and Sustainable Energy Reviews, 2013
- Operational results of grid‐connected photovoltaic system with different inverter's sizing factors (ISF)Progress in Photovoltaics: Research and Applications, 2006
- Optimal sizing of array and inverter for grid-connected photovoltaic systemsSolar Energy, 2006
- Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperatureSolar Energy, 2006
- Optimizing the panel area of a photovoltaic system in relation to the static inverter—Practical resultsSolar Energy, 1995
- Optimal sizing of grid-connected PV-systems for different climates and array orientations: a simulation studySolar Energy Materials and Solar Cells, 1994
- Optimal sizing of solar array and inverter in grid-connected photovoltaic systemsSolar Energy Materials and Solar Cells, 1994