Predictors of Success for Pulmonary Vein Isolation With Pulsed-field Ablation Using a Variable-loop Catheter With 3D Mapping Integration: Complete 12-month Outcomes From inspIRE
Authors:
- Tom De PotterTPTom De Potter
- Massimo GrimaldiMGMassimo Grimaldi
- Mattias DuytschaeverMDMattias Duytschaever
- Ante AnicAAAnte Anic
- Johan VijgenJVJohan Vijgen
- Petr NeuzilPNPetr Neuzil
- Hugo Van HerendaelHHHugo Van Herendael
- Atul VermaAVAtul Verma
- Allan SkanesASAllan Skanes
- Daniel ScherrDSDaniel Scherr
- Helmut PürerfellnerHPHelmut Pürerfellner
- Gediminas RackauskasGRGediminas Rackauskas
Open Access
- 1 May 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (5) , e012667
Abstract
BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study’s conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA 2 DS 2 -VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%–81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%–87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%–90.9%) or 94.0% (95% CI, 90.6%–97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04524364Keywords
This publication has 19 references indexed in Scilit:
- Effects of Electrode-Tissue Proximity on Cardiac Lesion Formation Using Pulsed Field AblationCirculation: Arrhythmia and Electrophysiology, 2022
- Composite Index Tagging for PVI in Paroxysmal AFJACC: Clinical Electrophysiology, 2022
- Primer on Pulsed Electrical Field AblationCirculation: Arrhythmia and Electrophysiology, 2021
- Pulsed-Field Ablation in Ventricular Myocardium Using a Focal CatheterCirculation: Arrhythmia and Electrophysiology, 2021
- Pulsed Field Ablation of Paroxysmal Atrial FibrillationJACC: Clinical Electrophysiology, 2021
- Circular Multielectrode Pulsed Field Ablation Catheter Lasso Pulsed Field AblationCirculation: Arrhythmia and Electrophysiology, 2021
- Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trialEP Europace, 2020
- Lattice-Tip Focal Ablation Catheter That Toggles Between Radiofrequency and Pulsed Field Energy to Treat Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2020
- Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial FibrillationJACC, 2019
- Ablation of Atrial Fibrillation With Pulsed Electric FieldsJACC: Clinical Electrophysiology, 2018