Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis
Authors:
- 6 October 2022
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 261 (4) , 989-998
Abstract
Purpose To assess the contribution of capsular tension ring (CTR) to postoperative stability and visual outcomes of a plate-haptic toric intraocular lens (IOL). Methods This prospective cohort study was performed among patients underwent toric IOL (AT TORBI 709 M) implantation with or without CTR at the Eye and ENT hospital between April 2020 and November 2021. Propensity score matching (PSM) was performed to balance baseline factors. Postoperatively, uncorrected distance visual acuity (UCVA) and residual astigmatism, as well as IOLs’ rotation, tilt, and decentration, were analyzed. Grouped multiple linear regression analysis was used to model predictive factors of rotation in each group. Additionally, a meta-analysis of data from 4 publications (284 eyes) and current study was performed to evaluate the effect of CTR co-implantation on toric IOL rotation. Results After PSM, 126 eyes from each group were included for further analysis. Postoperatively, UDVA was 0.31 ± 0.38 logMAR and 0.27 ± 0.36 logMAR in the CTR and NCTR groups, respectively (P = 0.441), and residual astigmatism was 0.75 ± 0.52 D and 0.86 ± 0.65 D, respectively (P = 0.139). The rotation of toric IOL was significantly smaller in the CTR group than in the NCTR group (4.63 ± 6.27 vs. 10.93 ± 16.05 degrees, P < 0.001). The regression models of the two groups and the coefficients of LT were significantly different (P < 0.001 and P = 0.001, respectively). Furthermore, the meta-analysis confirmed that CTR co-implantation reduced toric IOL rotation (MD, − 1.59; 95% CI, − 3.10 to − 0.09; P = 0.038). Conclusion CTR enhances rotational stability of toric IOL by reducing the impact of LT, and CTR co-implantation is recommended in patients with lens thickness (LT) ≥ 4.5 mm, white-to-white (WTW) ≥ 11.6 mm, or high preexisting astigmatism.Keywords
Funding Information
- Innovative Research Group Project of the National Natural Science Foundation of China (82171039)
- Xinjiang Production and Construction Corps (2020CB030)
This publication has 25 references indexed in Scilit:
- Combined Special Capsular Tension Ring and Toric IOL Implantation for Management of Astigmatism and High Axial Myopia with CataractsSeminars in Ophthalmology, 2016
- All about capsular tension ringsCurrent Opinion in Ophthalmology, 2015
- Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile rangeBMC Medical Research Methodology, 2014
- Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bagJournal of Cataract & Refractive Surgery, 2012
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Prevalence of corneal astigmatism before cataract surgeryJournal of Cataract & Refractive Surgery, 2009
- Predictability for proper capsular tension ring size and intraocular lens sizeKorean Journal of Ophthalmology, 2001
- Astigmatism and toric intraocular lensesCurrent Opinion in Ophthalmology, 2000
- Comparison of the effects of viscoelastic agents on clinical properties of the unfolder lens injection systemJournal of Cataract & Refractive Surgery, 1999
- Tests of Equality Between Sets of Coefficients in Two Linear RegressionsEconometrica, 1960