Abstract
The drivetrains of many utility-scale wind turbines have a gearbox connected with a doubly-fed induction generator (DFIG). Since gearbox failure is a major contributor to the high maintenance cost of wind turbines, it is important to perform fault diagnosis for gearboxes. In this paper, a new method that uses a DFIG stator current signal for the fault diagnosis of wind turbine drivetrain gearbox in nonstationary conditions is proposed. In the proposed method, the DC offset and high frequency noise of the current signal are first eliminated. Then, the envelope of the current signal is obtained by using the Hilbert transform. The current envelope signal only contains nonstationary frequencies that are proportional to the DFIG shaft rotating frequency. Next, a synchronous resampling algorithm is designed to convert the current envelope signal with a constant time interval to a resampled current envelope signal with a constant phase angle interval. Finally, the power spectral density (PSD) analysis is applied to the resampled current envelope signal for fault diagnosis. Laboratory test data collected from a 1/3 hp DFIG wind turbine drivetrain test rig and field data obtained from three 1.6 MW DFIG wind turbines are used to show the superiority of the proposed method.
Funding Information
  • Office of Energy Efficiency and Renewable Energy
  • U.S. Department of Energy (DE-EE0006802)
  • National Science Foundation (ECCS-1308045)

This publication has 32 references indexed in Scilit: