Reliability and Sensitivity of the TonoLab Rebound Tonometer in Awake Brown Norway Rats
Open Access
- 1 June 2009
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (6) , 2802-2808
Abstract
Purpose. To compare the sensitivity of the TonoLab rebound tonometer with the Tono-Pen in awake Brown Norway rats and to compare their ability to predict optic nerve damage induced by experimental IOP elevation. methods. TonoLab and Tono-Pen tonometers were calibrated in cannulated rat eyes connected to a pressure transducer. The TonoLab was used in awake animals housed in standard lighting to measure IOP during light and dark phases. Both instruments were used to monitor chronically elevated IOP produced by episcleral vein injection of hypertonic saline. Measured IOPs were correlated with quantified optic nerve damage in injected eyes. results. Although they were lower than transducer and Tono-Pen measurements at all levels, TonoLab readings showed an excellent linear fit with transducer readings from 20 to 80 mm Hg (R 2 = 0.99) in cannulated eyes. In awake animals housed in standard lighting, the TonoLab documented significantly higher pressures during the dark phase (27.9 ± 1.7 mm Hg) than during the light phase (16.7 ± 2.3 mm Hg). With elevated IOP, correlation between TonoLab and Tono-Pen readings (R 2 = 0.86, P < 0.0001) was similar to that in cannulated eyes. Although both instruments provided measurements that correlated well with optic nerve injury grade, only the Tono-Pen documented significant IOP elevation in eyes with the least amount of injury (P < 0.05). conclusions. The TonoLab is sensitive enough to be used in awake Brown Norway rats, though instrument fluctuation may limit its ability to identify significant pressure elevations in eyes with minimal optic nerve damage.Keywords
This publication has 53 references indexed in Scilit:
- Manometric Calibration and Comparison of TonoLab and TonoPen Tonometers in Rats With Experimental Glaucoma and in Normal MiceJournal of Glaucoma, 2006
- The Rate of Functional Recovery from Acute IOP ElevationInvestigative Ophthalmology & Visual Science, 2006
- Predictability and limitations of non-invasive murine tonometry: Comparison of two devicesExperimental Eye Research, 2006
- The use of cyclodialysis to limit exposure to elevated intraocular pressure in rat glaucoma modelsExperimental Eye Research, 2006
- Comparison of invasive and non-invasive tonometry in the mouseExperimental Eye Research, 2006
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- Characterization of retinal damage in the episcleral vein cauterization rat glaucoma modelExperimental Eye Research, 2006
- Noninvasive Measurement of Rodent Intraocular Pressure with a Rebound TonometerInvestigative Ophthalmology & Visual Science, 2005
- Activation of the Extracellular Signal-Regulated Kinase 1/2 Pathway by AAV Gene Transfer Protects Retinal Ganglion Cells in GlaucomaMolecular Therapy, 2005
- Functional assessment of glutamate clearance mechanisms in a chronic rat glaucoma model using retinal ganglion cell calcium imagingJournal of Neurochemistry, 2005