Success rate of miniscrews relative to their position to adjacent roots
Open Access
- 16 July 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 30 (4) , 330-335
Abstract
The purpose of this study was to evaluate, histologically, root contact, proximity to a root, and proximity to marginal bone level as possible risk factors for the failure of mini-screws when inserted between neighbouring teeth. Twenty mini-screws were inserted into the mandible of five beagle dogs. Each dog received two bracket screw bone anchors in each lower quadrant, between the roots of the second and third, and third and fourth premolars. Every six weeks, apical radiographs were taken and vital stains were administered. Twenty-five weeks after insertion of the screws, the dogs were sacrificed and specimens prepared for histological evaluation. The distance between the screw and the roots and between the screw and the marginal ridge level (MRL) were measured on the histological slides. The presence or absence of root contact was evaluated histologically on serial sections. The number of screws was too small to allow for sound statistical analysis of the factors under investigation. During the evaluation period, 11 screws were lost. Six screws were in contact with a tooth root and five of these were lost. In five sites, the distance between the screw and the tooth was less than 1.0 mm, but only one of these screws was lost. The distance between the screw and the marginal bone level was less than 1.0 mm for nine screws and seven of these were lost. The results of this limited study suggest that root contact and marginal position might be major risk factors for screw failure.Keywords
This publication has 16 references indexed in Scilit:
- Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Clinical use of miniscrew implants as orthodontic anchorage: Success rates and postoperative discomfortAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Ninety percent success in palatal implants loaded 1 week after placement: a clinical evaluation by resonance frequency analysisClinical Oral Implants Research, 2006
- Root repair after injury from mini‐screwClinical Oral Implants Research, 2005
- Dental implants for orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Do miniscrews remain stationary under orthodontic forces?American Journal of Orthodontics and Dentofacial Orthopedics, 2004
- The Use of Small Titanium Screws for Orthodontic AnchorageJournal of Dental Research, 2003
- Short epithetic implants for orthodontic anchorage in the paramedian region of the palateClinical Oral Implants Research, 2001
- Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applicationsClinical Oral Implants Research, 2001
- Factors associated with orthodontic patient compliance with intraoral elastic and headgear wearAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1990