The Effects of Screw Removal on Bone Strain in an Idealized Plated Bone Model
Authors:
- 1 May 1988
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 17 (3) , 111-116
Abstract
An idealized plated bone model was used to test the hypothesis that selected screw removal could alter the bone strain field and be a viable treatment for stress protection osteoporosis. Eighteen bone screw modifications were evaluated for their effects on bone strain. The three variables studied were number, position, and length of screws. Removal of two of four bone screws from an eight hole plate significantly increased the strain per load on the bone model over the values with eight screws in the plate (p < 0.05). The four screw configurations increased bone strain more than the six screw configurations. It also was shown that the position of screws in the plate could significantly alter the bone strain per load results. Removal of six bone screws from an eight hole plate also increased the bone strain per load, but to excess in some tests. In those configurations, the results were not statistically different from the unplated configuration. Replacement of the full length screws with eight half length screws that engaged only the near cortex significantly reduced bone strain per load as compared with eight bicortical bone screws.Keywords
This publication has 9 references indexed in Scilit:
- Changes in long‐bone structural properties during the first 8 weeks of plate implantationJournal of Orthopaedic Research, 1984
- Stress analysis of a simplified compression plate fixation system for fractured bonesComputers & Structures, 1983
- Functional adaptation of bone to increased stress. An experimental study.Journal of Bone and Joint Surgery, 1979
- Effects on intact femora of dogs of the application and removal of metal plates. A metabolic and structural study comparing stiffer and more flexible plates.Journal of Bone and Joint Surgery, 1978
- A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffnessJournal of Bone and Joint Surgery, 1976
- Force measurements in screw fixationJournal of Biomechanics, 1976
- Bone StrengthJournal of Bone and Joint Surgery, 1972
- The mechanical properties of surgical bone screws and some aspects of insertion practiceInjury, 1972
- Bone Structure Changes in the Dog Under Rigid Internal FixationClinical Orthopaedics and Related Research, 1971