Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal SPECT-PET/CT system
- 30 October 2023
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (1) , 135-142
Abstract
A dual-isotope simultaneous acquisition (DISA) of 99mTc and 18F affects the image quality of 99mTc by crosstalk and spill-over from 18F. We demonstrated the influence of spill-over and crosstalk on image quality and its correction effect for DISA SPECT with 99mTc and 18F. A fillable cylindrical chamber of 30 mm with NEMA-NU4 image quality phantom was filled with 99mTc only or a mixed 99mTc and 18F solution (C100). Two small-region chambers were filled with 99mTc only or a mixed 99mTc and 18F solution made at half the radioactivity concentration of C100 (C50) and non-radioactive water (C0). The 18F/99mTc ratio for DISA was set at approximately 0.4–12. Two types of 99mTc transverse images with and without scatter correction (SC and nonSC) were created. The 99mTc images of single-isotope acquisition (SIA) were created as a reference. The DISA/SIA ratio and contrast of 99mTc were compared between SIA and DISA. Although the DISA/SIA ratios with nonSC of C100, C50 and C0 gradually increased with increasing 18F/99mTc ratio, it was nearly constant by SC. The contrasts of C100 and C50 were similar to a reference value for both nonSC and SC. In conclusion, DISA images showed lower image quality as the 18F/99mTc ratio increased. The image quality in hot-spot regions such as C100 and C50 was improved by SC, whereas cold-spot regions such as C0 could not completely remove the influence of spill-over even with SC.Keywords
Funding Information
- Japan Society for the Promotion of Science (18K15628)
This publication has 33 references indexed in Scilit:
- Performance Assessment of a Preclinical PET Scanner with Pinhole Collimation by Comparison to a Coincidence-Based Small-Animal PET ScannerJournal of Nuclear Medicine, 2014
- VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PETJournal of Nuclear Medicine, 2012
- Pixel-based subsets for rapid multi-pinhole SPECT reconstructionPhysics in Medicine & Biology, 2010
- Quantitative evaluation of simultaneous reconstruction with model‐based crosstalk compensation for dual‐isotope simultaneous acquisition brain SPECTMedical Physics, 2009
- Prediction of functional recovery after revascularization in patients with chronic ischaemic left ventricular dysfunction: head-to-head comparison between 99mTc-sestamibi/18F-FDG DISA SPECT and 13N-ammonia/18F-FDG PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Myocardial distribution of 18F-FDG and 99mTc-sestamibi on dual-isotope simultaneous acquisition SPET compared with PETEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Simultaneous 99mTc/201Tl dual-isotope SPET with Monte Carlo-based down-scatter correctionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Clinical value of triple-energy window scatter correction in simultaneous dual-isotope single-photon emission tomography with123I-BMIPP and201TIEuropean Journal of Nuclear Medicine and Molecular Imaging, 1997
- Evaluation of SPET quantification of simultaneous emission and transmission imaging of the brain using a multidetector SPET system with the TEW scatter compensation method and fan-beam collimationEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- A practical method for position-dependent Compton-scatter correction in single photon emission CTIEEE Transactions on Medical Imaging, 1991