Evaluation of ventricular-arterial coupling by impedance cardiography in healthy volunteers
- 1 November 2019
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (11) , 115002
Abstract
Background : The interplay between cardiac function and the arterial system is currently defined as ventricular-arterial coupling (VAC) and it is an expression of global cardiovascular efficiency. VAC involves a variety of complex interactions between the heart and the vasculature. A basic index of VAC is the ratio of effective arterial elastance (Ea)/ end-systolic elastance (Ees). While this is often done with echocardiography, obtaining Ea/Ees using impedance cardiography is feasible, although this possibility has not been explored so far. Objective : The aim of this study was to compare the Ea/Ees values obtained using echocardiography and impedance cardiography. Approach : Two independent operators estimated Ea/Ees in 91 (41 ± 14 years old, women 51%) untreated apparently healthy individuals using (1) Doppler echocardiography with the single-beat method developed by Chen et al (2001 J. Am. Coll. Cardiol . 38 2028–34); and (2) data provided by impedance cardiography. The differences between Ea/Ees values were compared and correlation between both methods was estimated. Main results : Although Ea and Ees values calculated by impedance cardiography were lower than those estimated by echocardiography (−0.201 ± 0.457 mmHg ml −1 and −0.193 ± 0.413 mmHg ml −1 ), Ea/Ees ratio values were similar. Thus, there was no significant difference between the mean values of Ea/Ees estimated by impedance cardiography or echocardiography (Ea/Ees impedance cardiography − Ea/Ees echocardiography = −0.015 ± 0.096, p = 0.150). Ea/Ees values calculated by both methods were highly correlated ( r = 0.85, p < 0.001), as well as the pre-ejection and left ventricular ejection time ( r = 0.83 and r = 0.91, respectively). Significance : In healthy individuals, estimation of Ea/Ees by impedance cardiography yielded similar values to those obtained using echocardiography.Keywords
This publication has 16 references indexed in Scilit:
- The Role of Ventricular–Arterial Coupling in Cardiac Disease and Heart Failure: Assessment, Clinical Implications and Therapeutic Interventions. A Consensus Document of the European Society of Cardiology Working Group on Aorta & Peripheral Vascular Diseases, European Association of Cardiovascular Imaging, and Heart Failure AssociationEuropean Journal of Heart Failure, 2019
- Effective Arterial Elastance Is Insensitive to Pulsatile Arterial LoadHypertension, 2014
- The ventricular-arterial coupling: From basic pathophysiology to clinical application in the echocardiography laboratoryJournal of Cardiovascular Echography, 2013
- Ventricular–arterial coupling: Invasive and non-invasive assessmentArtery Research, 2013
- Arterial-ventricular coupling: mechanistic insights into cardiovascular performance at rest and during exerciseJournal of Applied Physiology, 2008
- Where to B in dZ/dtPsychophysiology, 2006
- Noninvasive single-beat determination of left ventricular end-systolic elastance in humansJACC, 2001
- Stability of cardiac impedance measures: Aortic opening (B-point) detection and scoringBiological Psychology, 1993
- Effective arterial elastance as index of arterial vascular load in humans.Circulation, 1992
- MEASUREMENT OF EJECTION FRACTION BY BIOIMPEDANCE METHODCritical Care Medicine, 1987