Refractive and Visual Outcomes of SMILE for Compound Myopic Astigmatism With the VISUMAX 800
Authors:
- Dan Z. ReinsteinDRDan Z. Reinstein
- Timothy J. ArcherTATimothy J. Archer
- Joseph G. PotterJPJoseph G. Potter
- Ruchi GuptaRGRuchi Gupta
- Rainer WiltfangRWRainer Wiltfang
- 1 May 2023
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 39 (5) , 294-301
Abstract
Purpose: To report the first refractive and visual outcomes of small incision lenticule extraction (SMILE) using the VISUMAX 800 femtosecond laser (Carl Zeiss Meditec AG). Methods: This was a retrospective analysis of consecutive eyes treated by SMILE using the VISUMAX 800 femtosecond laser at London Vision Clinic, EuroEyes Group, London, United Kingdom. Inclusion criteria were patients aged younger than 45 years, a corrected distance visual acuity (CDVA) of 20/20 or better, and the 3-month postoperative timepoint data being available for analysis. Standard outcomes analysis and vector analysis by the Alpins method were performed. Results: During the study period, 128 eyes of 66 consecutive patients were treated. Three-month data were available for 118 eyes (92%), and 10 eyes (8%) were lost to follow-up. The mean attempted spherical equivalent refraction (SEQ) was −4.65 ± 1.91 diopters (D) (range: −1.90 to −10.05 D) and the mean cylinder was −0.98 ± 0.78 D (range: 0.00 to −4.00 D). The mean age was 30 ± 5 years (range: 20 to 43 years), with 54% women and 46% men. Postoperative SEQ was within ±0.50 D in 86% and ±1.00 D in 100% of eyes. Uncorrected distance visual acuity was 20/20 or better in 91% of eyes. One line of CDVA was lost in 8% of eyes, and no eyes lost two or more lines. There was a small but statistically significant increase in contrast sensitivity at 3, 6, 12, and 18 cpd. Conclusions: Early outcomes data for SMILE with the second generation VISUMAX 800 femtosecond laser demonstrated an effective and safe option equivalent to published first generation VisuMax outcomes for the treatment myopia and astigmatism. [ J Refract Surg . 2023;39(5):294–301.]Keywords
This publication has 18 references indexed in Scilit:
- Lower Energy Levels Improve Visual Recovery in Small Incision Lenticule Extraction (SMILE)Journal of Refractive Surgery, 2016
- Quality control outcomes analysis of small-incision lenticule extraction for myopia by a novice surgeon at the first refractive surgery unit in Nepal during the first 2 years of operationJournal of Cataract & Refractive Surgery, 2016
- Optical Zone Centration Accuracy Using Corneal Fixation-based SMILE Compared to Eye Tracker-based Femtosecond Laser-assisted LASIK for MyopiaJournal of Refractive Surgery, 2015
- Comparison of Visual and Refractive Outcomes Following Femtosecond Laser-Assisted LASIK With SMILE in Patients With Myopia or Myopic AstigmatismJournal of Refractive Surgery, 2014
- Comparison of the Visual Results After SMILE and Femtosecond Laser-Assisted LASIK for MyopiaJournal of Refractive Surgery, 2014
- Epithelial Remodeling as Basis for Machine-Based Identification of KeratoconusInvestigative Ophthalmology & Visual Science, 2014
- Reproducibility of manifest refraction between surgeons and optometrists in a clinical refractive surgery practiceJournal of Cataract & Refractive Surgery, 2014
- Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgeryJournal of Cataract & Refractive Surgery, 2011
- Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective studyBritish Journal of Ophthalmology, 2010
- Corneal Epithelial Thickness Profile in the Diagnosis of KeratoconusJournal of Refractive Surgery, 2009