High Revision Rate at 5 Years after Hip Resurfacing with the Durom Implant
Authors:
- 1 September 2011
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (9) , 2598-2604
Abstract
There is growing evidence that different resurfacing implants are associated with variable survival and revision rates. A registry analysis indicated the Durom resurfacing implant had high revision rates at 5 years, whereas three original studies reported low revision rates at short-term followups. Thus, the revision rates appear controversial. We therefore assessed (1) the survivorship including differences between women and men at a mean of 5 years after resurfacing with the Durom implant, and (2) clinical scores and radiographic parameters. We prospectively followed all 100 Durom hip resurfacings implanted in 91 patients (25 women and 66 men; mean age, 52 years) between 2003 and 2004. Survivorship analysis was performed with pending revision or revision for any reason as the endpoint. The minimum followup was 47 months (mean, 60 months; range, 47–72 months). At a mean of 5 years, 11 hips were revised for various reasons. Cumulative survival was 88.2% for all patients and 81.5% for women. The mean Oxford (OHS) and Harris hip (HHS) scores were 14.6 and 94.7, respectively. The mean UCLA activity level was 7.9. Sclerotic changes around the short femoral stem (pedestal sign) were detected in 40% of the hips. We observed considerable femoral neck thinning with component-to-neck ratios of 0.85 preoperatively and 0.82 at 5 years. Our study highlights a high revision rate 5 years after hip resurfacing with the Durom implant. This observation underlines previous findings from registry data and suggests that revision rates increase with time. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 40 references indexed in Scilit:
- The influence of the size of the component on the outcome of resurfacing arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2010
- Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revisionActa Orthopaedica, 2010
- Hip Resurfacing Data from National Joint Registries: What Do They Tell Us? What Do They Not Tell Us?Clinical Orthopaedics and Related Research, 2010
- Failure of the Durom Metasul® Acetabular ComponentClinical Orthopaedics and Related Research, 2010
- Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplastiesActa Orthopaedica, 2009
- Operationstechnik und klinische Ergebnisse des DUROM™-Hip-Resurfacing-Systems mit dem lateralen ZugangOperative Orthopädie und Traumatologie, 2009
- Reliability and Validity of the Cross-Culturally Adapted German Oxford Hip ScoreClinical Orthopaedics and Related Research, 2008
- Outcome of Hip Resurfacing Arthroplasty in Patients with Developmental Hip DysplasiaClinical Orthopaedics and Related Research, 2008
- Which is the Best Activity Rating Scale for Patients Undergoing Total Joint Arthroplasty?Clinical Orthopaedics and Related Research, 2008
- The Influence of Surgical Approach on Outcome in Birmingham Hip ResurfacingClinical Orthopaedics and Related Research, 2008