Weaning Automation with Adaptive Support Ventilation: A Randomized Controlled Trial in Cardiothoracic Surgery Patients
Authors:
- Dave A. DongelmansDDDave A. Dongelmans
- Denise P. VeeloDVDenise P. Veelo
- Frederique PaulusFPFrederique Paulus
- Bas A. J. M. de MolBMBas A. J. M. de Mol
- Johanna C. KorevaarJKJohanna C. Korevaar
- Anna KudogaAKAnna Kudoga
- Pauline MiddelhoekPMPauline Middelhoek
- Jan M. BinnekadeJBJan M. Binnekade
- Marcus J. SchultzMSMarcus J. Schultz
- 1 February 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 108 (2) , 565-571
Abstract
Adaptive support ventilation (ASV) is a microprocessor-controlled mode of mechanical ventilation that switches automatically from controlled ventilation to assisted ventilation and selects ventilatory settings according to measured lung mechanics. In a randomized controlled trial, non-fast-track coronary artery bypass grafting patients' lungs were ventilated with ASV or pressure-controlled/pressure-support ventilation (control) to compare time until tracheal extubation, duration of controlled ventilation versus assisted ventilation, and ventilation characteristics. One hundred twenty-eight consecutive patients were randomized. ASV patients had their tracheas extubated after median 16.4 and interquartile range 12.5-20.8 hr, and control patients after 16.3 (13.7-19.3) hr, respectively (P = 0.97). The percentage of time patients were on assisted ventilation (expressed as the median percentage of total duration of ventilation) was 43% (28%-67%) in the ASV group and 52% (33%-75%) in the control group (P < 0.05). However, the number of switches from controlled to assisted ventilation was higher in the ASV group (43.0 [14.0-74.0]) than in the control group (4.0 [2.0-9.0]) (P < 0.001). In ASV patients, mean tidal volumes were significantly larger during controlled ventilation than in control patients (8.6 +/- 0.8 mL/kg predicted body weight vs 7.1 +/- 1.4 mL/kg predicted body weight; P = 0.05), and no differences in tidal volumes were found during assisted ventilation. Weaning automation with ASV is feasible and safe in non-fast-track coronary artery bypass grafting patients. Time until tracheal extubation with ASV equals time until tracheal extubation with standard weaning and allows for frequent (automatic) switches between controlled and assisted ventilation.Keywords
This publication has 10 references indexed in Scilit:
- Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated HumansNew England Journal of Medicine, 2008
- Automatic selection of breathing pattern using adaptive support ventilationIntensive Care Medicine, 2007
- What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?Anesthesiology, 2007
- The impact of spontaneous breathing during mechanical ventilationCurrent Opinion in Critical Care, 2006
- Automatic “Respirator/Weaning” with Adaptive Support Ventilation: The Effect on Duration of Endotracheal Intubation and Patient ManagementAnesthesia & Analgesia, 2003
- Clinical experience with adaptive support ventilation for fast-track cardiac surgeryJournal of Cardiothoracic and Vascular Anesthesia, 2003
- Medical automation—a technologically enhanced work environment to reduce the burden of care on nursing staff and a solution to the health care cost crisisNursing Outlook, 2003
- Adaptive Support Ventilation for Fast Tracheal Extubation after Cardiac SurgeryAnesthesiology, 2001
- Fast-track recovery of the coronary bypass patientThe Annals of Thoracic Surgery, 1994
- Ordering and Administration of Sedatives and Analgesics During the Withholding and Withdrawal of Life Support From Critically III PatientsJAMA, 1992