Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties
Authors:
- Christopher JantzenCJChristopher Jantzen
- Henrik L JørgensenHJHenrik L Jørgensen
- Benn R DuusBDBenn R Duus
- Sune L SporringSSSune L Sporring
- Jes B LauritzenJLJes B Lauritzen
Open Access
- 18 April 2013
- journal article
- review article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 84 (3) , 229-236
Abstract
Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties. Studies were searched for in the Medline database, Embase, and the Cochrane Database of Systematic Reviews. Highest mean or median ion concentrations of Cr and Co after a minimum of 1 year of follow-up were extracted and grouped according to sample- and articulation type, and average values were calculated. 43 studies were included and 16 different MoM implants were identified. For the different types of bearings, average ion concentrations and range were calculated from the mean or median ion concentration. The average Cr concentration ranged between 0.5 and 2.5 μg/L in blood and between 0.8 and 5.1 μg/L in serum. For Co, the range was 0.7-3.4 μg/L in blood and 0.3-7.5 μg/L in serum. When the average blood ion concentrations calculated for the different implants, together with the concentrations measured in the individual studies, were compared with the upper acceptable limit for Cr and Co in blood, no clear pattern was recognized. Furthermore, we were unable to detect any clear difference in ion concentrations between different types of implants (THA and resurfacing).Keywords
This publication has 69 references indexed in Scilit:
- Serum Metal Ion Concentrations After Unilateral vs Bilateral Large-Head Metal-on-Metal Primary Total Hip ArthroplastyThe Journal of Arthroplasty, 2011
- Comparison of Whole-Blood Metal Ion Levels in Four Types of Metal-on-Metal Large-Diameter Femoral Head Total Hip Arthroplasty: The Potential Influence of the Adapter SleeveJournal of Bone and Joint Surgery, 2011
- A Prospective Metal Ion Study of Large-Head Metal-on-Metal Bearing: A Matched-Pair Analysis of Hip Resurfacing Versus Total Hip ReplacementOrthopedic Clinics of North America, 2011
- Characterization of the Running-in Period in Total Hip Resurfacing Arthroplasty: An in Vivo and in Vitro Metal Ion AnalysisJournal of Bone and Joint Surgery, 2008
- Pseudotumours associated with metal-on-metal hip resurfacingsThe Journal of Bone and Joint Surgery. British volume, 2008
- Does Ion Release Differ Between Hip Resurfacing and Metal-on-metal THA?Clinical Orthopaedics and Related Research, 2008
- How Do Serum Cobalt and Chromium Levels Change after Metal-on-Metal Hip Resurfacing?Clinical Orthopaedics and Related Research, 2005
- Distribution of Cobalt Chromium Wear and Corrosion Products and Biologic ReactionsClinical Orthopaedics and Related Research, 1996
- Health risks associated with cobalt exposure — an overviewScience of The Total Environment, 1994
- Is there a role for reactive oxygen species in the mechanism of chromium(VI) carcinogenesis?Chemical Research in Toxicology, 1991