Calibration of NO sensors for in-vivo voltammetry: laboratory synthesis of NO and the use of UV?visible spectroscopy for determining stock concentrations
Authors:
- 23 February 2005
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 381 (4) , 964-971
Abstract
The increasing scientific interest in nitric oxide (NO) necessitates the development of novel and simple methods of synthesising NO on a laboratory scale. In this study we have refined and developed a method of NO synthesis, using the neutral Griess reagent, which is inexpensive, simple to perform, and provides a reliable method of generating NO gas for in-vivo sensor calibration. The concentration of the generated NO stock solution was determined using UV–visible spectroscopy to be 0.28±0.01 mmol L−1. The level of NO −2 contaminant, also determined using spectroscopy, was found to be 0.67±0.21 mmol L−1. However, this is not sufficient to cause any considerable increase in oxidation current when the NO stock solution is used for electrochemical sensor calibration over physiologically relevant concentrations; the NO sensitivity of bare Pt-disk electrodes operating at +900 mV (vs. SCE) was 1.08 nA μmol−1 L, while that for NO −2 was 5.9×10−3 nA μmol−1 L. The stability of the NO stock solution was also monitored for up to 2 h after synthesis and 30 min was found to be the time limit within which calibrations should be performed.Keywords
This publication has 42 references indexed in Scilit:
- Traffic pollution in a downtown site of Buenos Aires CityAtmospheric Environment, 2001
- Peroxidase enzyme electrodes as nitric oxide biosensorsAnalytica Chimica Acta, 2000
- Amperometric Nitric Oxide Sensors: a Comparative StudyElectroanalysis, 1998
- Direct Measurements of Endothelium-Derived Nitric Oxide Release by Stimulation of Endothelin Receptors in Rat Kidney and Its Alteration in Salt-Induced HypertensionCirculation, 1995
- Nitric Oxide:Biochemistry, Pathophysiology, and DetectionAmerican Journal of Clinical Pathology, 1993
- An electrochemical microprobe for detecting nitric oxide release in brain tissueNeuroscience Research, 1990
- Observational evidence of ozone depletion by nitric oxide at 40 km downwind of a medium size cityAtmospheric Environment. Part A. General Topics, 1990
- Endothelium-derived relaxing factor produced and released from artery and vein is nitric oxide.Proceedings of the National Academy of Sciences of the United States of America, 1987
- Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factorNature, 1987
- Bolide impacts, acid rain, and biospheric traumas at the Cretaceous-Tertiary boundaryEarth and Planetary Science Letters, 1987