Quantitative Comparison of the Vascular Structure of Macular Neovascularizations Between Swept-Source and Spectral-Domain Optical Coherence Tomography Angiography
Open Access
- 1 October 2020
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3179-3186
Abstract
Purpose: The aim of this study was to ascertain and quantify the differences between swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA) imaging of macular neovascularizations (MNV) in neovascular age-related macular degeneration (nAMD). Patients and Methods: SD-OCTA (RTVue Avanti) and SS-OCTA (PLEX® Elite 9000) were performed in 37 patients with MNV in nAMD. The MNV was delineated and the data were processed via ImageJ. The parameters MNV area, nodes per area, fractal dimension (FD), and flow density were analyzed using MatLab. Results: There was close agreement between the two devices regarding MNV area (ICCc 0.977, ICCa 0.977, R2 0.977), but only slight agreement regarding nodes per area (ICCa 0.008, ICCc 0.548, R2 0.51), FD (ICCa 0.425, ICCc 0.846, R2 0.96), and flow density (ICCa 0.451, ICCc 0.656, R2 0.65). The difference between the two devices was insignificant for MNV area (type 1: p=0.328; type 2: p=0.426; type 3: p=0.615), but significant for nodes per area (type 1: p=0.002; type 2: p=0.00001; type 3: p=0.003), FD (type 1: p< 0.00001; type 2: p< 0.00001; type 3: p=0.015) and flow density (type 1: p=0.0004; type 2: p=0.004; type 3: p=0.052). Conclusion: MNV area is closely comparable between devices using SS-OCTA and SD-OCTA imaging. However, the two methods differ significantly in their precise assessment of the vascular morphology (FD, flow density, nodes per area). Therefore, results obtained using different devices are not comparable and should not be amalgamated in clinical trials.Keywords
This publication has 25 references indexed in Scilit:
- Projection Artifact Removal Improves Visualization and Quantitation of Macular Neovascularization Imaged by Optical Coherence Tomography AngiographyOphthalmology Retina, 2017
- Identification and clinical role of choroidal neovascularization characteristics based on optical coherence tomography angiographyActa Ophthalmologica, 2017
- Choroidal Neovascularization Analyzed on Ultrahigh-Speed Swept-Source Optical Coherence Tomography Angiography Compared to Spectral-Domain Optical Coherence Tomography AngiographyAmerican Journal of Ophthalmology, 2016
- OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY VERSUS TRADITIONAL MULTIMODAL IMAGING IN ASSESSING THE ACTIVITY OF EXUDATIVE AGE-RELATED MACULAR DEGENERATIONRetina, 2015
- Comparisons of Choroidal Thickness of Normal Eyes Obtained by Two Different Spectral-Domain OCT Instruments and One Swept-Source OCT InstrumentInvestigative Ophthalmology & Visual Science, 2013
- Incomplete blinking: Exposure keratopathy, lid wiper epitheliopathy, dry eye, refractive surgery, and dry contact lensesContact Lens and Anterior Eye, 2007
- Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patientsJournal of Biomedical Optics, 2007
- Multi-scale Midline Extraction Using Creaseness2005
- Local connected fractal dimensions and lacunarity analyses of 60 degrees fluorescein angiograms.1995
- A Method of Photographing Fluorescence in Circulating Blood in the Human RetinaCirculation, 1961