Is the Expense of Equipment and Testing Time of Calorimetry Truly Justified? Stray Load Loss Efficiency Connections
Authors:
- 2 August 2004
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 10 (3) , 62-69
Abstract
This paper deals about the stray load loss efficiency in electrical machines. Induction motors are the most commonly employed electrical machines, in industries. When examining the losses of an induction machine, it is possible to identify the "conventional" losses that include stator and rotor conductor losses, magnetic core loss, frication and windage loss. However induction motors also have an additional power loss component termed "stray load loss" (SLL) which is caused by practical nature of the machine. However, SLL is very significant part of overall losses that may have a big influence on the temperature situation of the motor. The evaluation of SLL in induction motors is an important part of the efficiency estimation process. The use of calorimetry precisely determines the stray load loss.Keywords
This publication has 6 references indexed in Scilit:
- Comparison testing of IEEE Standard 841 motors2002
- Stray Losses in Induction Machines: Part II, Calculation and ReductionIEEE Transactions on Power Apparatus and Systems, 1985
- Stray Losses in Induction Machines: Part I, Definition, Origin and MeasurementIEEE Transactions on Power Apparatus and Systems, 1985
- Determination of load losses and torques in squirrel-cage induction motorsProceedings of the Institution of Electrical Engineers, 1966
- Origins of load losses in induction motors with cast aluminium rotorsProceedings of the Institution of Electrical Engineers, 1965
- Survey of basic stray losses in squirrel-cage induction motorsProceedings of the Institution of Electrical Engineers, 1964