Biofunctionalized Conducting Polymer/Carbon Microfiber Electrodes for Ultrasensitive Neural Recordings
- 25 November 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 7 (48) , 27016-27026
Abstract
Carbon microfibers (MFs) coated with conducting polymers may provide a solution for long-term recording of activity from individual or small groups of neurons. Attaching cell adhesion molecules to the electro-sensitive surface might further improve electrode–neuron contact, thus enhancing signal stability and fidelity. We fabricated biofunctionalized microelectrodes consisting of 7-μm diameter carbon MFs coated with poly(3,4-ethylenedioxythiophene) doped with poly[(4-styrenesulfonic acid)-co-(maleic acid)] (PEDOT:PSS-co-MA), and linked N-Cadherin to the polymer surface. These electrodes were tested for recording artificially generated electric potentials, as well as multiunit activity (MUA), sharp wave-ripple complexes (SWRs), and field excitatory postsynaptic potentials (fEPSPs) in rat hippocampal slices. The effects of electrode length and functionalization were compared. PEDOT:PSS-co-MA coating improved electric current detection and reduced the electrical noise but had no significant effect on the amp...Keywords
Funding Information
- Instituto de Salud Carlos III
- Ministerio de Economía y Competitividad (PI12/02835)
- Eropean Regional Development Fund (PI12/02835)
This publication has 47 references indexed in Scilit:
- BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performanceBiomaterials, 2015
- Carbon‐Nanotube‐Modified Electrodes for Highly Efficient Acute Neural RecordingAdvanced Healthcare Materials, 2013
- A carbon-fiber electrode array for long-term neural recordingJournal of Neural Engineering, 2013
- Combined macro-/mesoporous microelectrode arrays for low-noise extracellular recording of neural networksJournal of Neurophysiology, 2012
- Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodesJournal of Neural Engineering, 2011
- Polymers for neural implantsJournal of Polymer Science Part B: Polymer Physics, 2010
- Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegenerationJournal of Neural Engineering, 2009
- Implanted Neural Interfaces: Biochallenges and Engineered SolutionsAnnual Review of Biomedical Engineering, 2009
- Response of brain tissue to chronically implanted neural electrodesJournal of Neuroscience Methods, 2005
- Carbon Fiber as an Electrode MaterialIEEE Transactions on Biomedical Engineering, 1982