Ceramic component fracture following trauma in a bilateral total hip arthroplasty
- 16 November 2026
- journal article
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
Abstract
Background: Ceramic-on-ceramic total hip arthroplasty has demonstrated excellent wear characteristics and long-term survivorship. Nevertheless, ceramic component fracture remains a rare but potentially devastating complication. Traumatic events may contribute to failure even in previously well-functioning implants. Case Presentation: We report the case of a 66-year-old male who underwent a bilateral ceramic-on-ceramic total hip arthroplasty. The postoperative course was uneventful, and the patient remained asymptomatic with satisfactory function. Three years after the surgery, he sustained an accidental fall. Subsequently, he reported an audible noise originating from the left hip, followed by progressive pain and severe functional limitation. Radiographic and computed tomography (CT) scan evaluation suggested a fracture of the ceramic bearing. Revision surgery was performed, during which the ceramic head and acetabular insert were exchanged. The postoperative course was favourable. Conclusion: Although uncommon, ceramic component fracture should be suspected in patients presenting with hip noise, pain, and functional deterioration, particularly following trauma. Early diagnosis and prompt revision are essential to prevent further joint damage and optimize clinical outcomes.This publication has 22 references indexed in Scilit:
- Late-onset atraumatic ceramic head fracture in a ceramic-on-ceramic total hip arthroplasty: a case reportSkeletal Radiology, 2026
- Should Ceramic-on-Ceramic or Ceramic-on-Polyethylene Bearings Be Preferred in Revision Total Hip Arthroplasty After Ceramic Head or Liner Fracture? A Retrospective Multicenter Case-Control Study of 33 CasesOrthopaedics & Traumatology: Surgery & Research, 2025
- Revision Hip Arthroplasty After Fractured Ceramic Bearings Using Ceramic–on–Ceramic Surfaces: Long-Term Clinical and Radiological Outcomes of 36 CasesThe Journal of Arthroplasty, 2025
- Management and Outcomes of Breakage in Polyethylene-Ceramic Composite (Sandwich-type) Liners: Lessons From Long-term Follow-upArthroplasty Today, 2025
- Fourth-generation Ceramic Head Fracture in Total Hip Arthroplasty: A Case Report and Literature ReviewArthroplasty Today, 2025
- Revision of Ceramic Head Fracture After Third Generation Ceramic-on-Ceramic Total Hip ArthroplastyThe Journal of Arthroplasty, 2014
- Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 YearsClinical Orthopaedics and Related Research, 2012
- Fractures of a sandwich ceramic liner at ten year follow-upInternational Orthopaedics, 2011
- Thirty years of experience with alumina-on-alumina bearings in total hip arthroplastyInternational Orthopaedics, 2010
- Alumina Inlay Failure in Cemented Polyethylene-backed Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2008