Hanging protocol optimization of lumbar spine radiographs with machine learning
Author:
- 15 February 2021
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 50 (9) , 1809-1819
Abstract
Objectives The purpose of this study was to determine whether machine learning algorithms can be utilized to optimize the hanging protocol of lumbar spine radiographs. Specifically, we explored whether machine learning models can accurately label lumbar spine views/positions, detect hardware, and rotate the lateral views to straighten the image. Methods We identified 1727 patients with 6988 lumbar spine radiographs. The view (anterior-posterior, right oblique, left oblique, left lateral, right lateral, left lumbosacral or right lumbosacral), hardware (present or not present), dynamic position (neutral, flexion, or extension), and correctional rotation of each radiograph were manually documented by a board-certified radiologist. Various output metrics were calculated, including area under the curve (AUC) for the categorical output models (view, hardware, and dynamic position). For non-binary categories, an all-versus-other technique was utilized designating one category as true and all others as false, allowing for a binary evaluation (e.g., AP vs. non-AP or extension vs. non-extension). For correctional rotation, the degree of rotation required to straighten the lateral spine radiograph was documented. The mean absolute difference was calculated between the ground truth and model-predicted value reported in degrees of rotation. Ensembles of the rotation models were created. We evaluated the rotation models on 3 test dataset splits: only 0 rotation, only non-0 rotation, and all cases. Results The AUC values for the categorical models ranged from 0.985 to 1.000. For the only 0 rotation data, the ensemble combining the absolute minimum value between the 20- and 60-degree models performed best (mean absolute difference of 0.610). For the non-0 rotation data, the ensemble merging the absolute maximum value between the 40- and 160-degree models performed best (mean absolute difference of 4.801). For the all cases split, the ensemble combining the minimum value of the 20- and 40-degree models performed best (mean absolute difference of 3.083). Conclusion Machine learning techniques can be successfully implemented to optimize lumbar spine x-ray hanging protocols by accounting for views, hardware, dynamic position, and rotation correction.Keywords
Funding Information
- National Institutes of Health (UL1 TR001857)
This publication has 16 references indexed in Scilit:
- The exploration of feature extraction and machine learning for predicting bone density from simple spine X-ray images in a Korean populationSkeletal Radiology, 2019
- Ankle Fracture Detection Utilizing a Convolutional Neural Network Ensemble Implemented with a Small Sample, De Novo Training, and Multiview IncorporationJournal of Digital Imaging, 2019
- Convolutional Neural Networks for Automated Fracture Detection and Localization on Wrist RadiographsRadiology: Artificial Intelligence, 2019
- Binomial Classification of Pediatric Elbow Fractures Using a Deep Learning Multiview Approach Emulating Radiologist Decision MakingRadiology: Artificial Intelligence, 2019
- Computerized Bone Age Estimation Using Deep Learning Based Program: Evaluation of the Accuracy and EfficiencyAmerican Journal of Roentgenology, 2017
- Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization2017
- Artificial intelligence for analyzing orthopedic trauma radiographsActa Orthopaedica, 2017
- Densely Connected Convolutional Networks2017
- SU‐E‐T‐33: Pydicom: An Open Source DICOM LibraryMedical Physics, 2011
- Matplotlib: A 2D Graphics EnvironmentComputing in Science & Engineering, 2007