Central Corneal Thickness Measurements with Optical Coherence Tomography and Ultrasound Pachymetry in Healthy Subjects and in Patients after Photorefractive Keratectomy
- 1 March 2009
- journal article
- research article
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 19 (2) , 180-187
Abstract
Purpose: To compare central corneal thickness measurements made using two different methods, optical coherence tomography (OCT) and ultrasound pachymetry, applied both in normal eyes and in eyes on which photorefractive keratectomy (PRK) had been performed. A second objective was to assess the intrasession variability of OCT measurements. Methods: In this prospective study, central corneal thickness was measured in 20 normal subjects (normal group) and in 20 PRK patients using the StratusOCT instrument model 3000 (Carl Zeiss Meditec), and also with an ultrasound pachymeter. Five OCT measurements were performed using the Fast Macular Thickness protocol. Corneal thickness data were obtained with the Scan Profile analysis protocol. The OCT measurement results were compared with the mean value of three ultrasound pachymetry measurements for the same eye. Results: The pachymetry–OCT correlation coefficients were 0.96 and 0.97 in the normal and PRK groups, respectively (p=0.14). Neither linear regression nor Bland-Altmann analysis revealed any significant systematic measurement error. Intrasession standard deviations in the normal and PRK groups were 4.9 μm and 3.8 μm, respectively. Conclusions: Noncontact central corneal thickness measurements made using the StratusOCT instrument are accurate and reproducible, both in normal subjects and in post-PRK patients. The instrument system does not need any modifications to correctly detect and measure the center of the cornea.Keywords
This publication has 14 references indexed in Scilit:
- Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomographyClinical & Experimental Ophthalmology, 2006
- The Repeatability of Corneal and Corneal Epithelial Thickness Measurements Using Optical Coherence TomographyOptometry and Vision Science, 2006
- Corneal and Epithelial Thickness in Keratoconus: A Comparison of Ultrasonic Pachymetry, Orbscan II, and Optical Coherence TomographyJournal of Refractive Surgery, 2006
- Central Corneal Thickness Measurement in Clinical PracticeJournal of Glaucoma, 2005
- Repeatability and Reproducibility of Central Corneal Thickness Measurement With Pentacam, Orbscan, and UltrasoundOptometry and Vision Science, 2005
- Assessment of central corneal thickness using optical coherence tomographyJournal of Cataract & Refractive Surgery, 2005
- Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetryEye, 2002
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986