Impact of the Field Winding Interturn Short-Circuit Position on Rotor Vibration Properties in Synchronous Generators
Open Access
- 30 November 2021
- journal article
- research article
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2021, 1-11
Abstract
This paper investigates the effect of the field winding interturn short-circuit (FWISC) position on the rotor vibration properties in turbo generators. Different from the previous studies which focused on the influence of the short-circuit degree, this work pays much attention to the impact of the short-circuit position on the rotor unbalanced magnetic pull (UMP) properties and vibration characteristics. The theoretical UMP model is firstly deduced based on the analysis of the magnetic flux density (MFD) variation. Then, the finite element analysis (FEA) is performed to calculate the UMP data. Finally, the rotor vibrations are tested on a CS-5 prototype generator which has two poles and a rated capacity of 5 kVA. It is shown that the occurrence of FWISC will greatly increase the UMP as well as the rotor vibration. In addition to the short-circuit degree, the short-circuit position will also affect the UMP and vibration. The nearer the short-circuit position is to the big rotor teeth, the larger the UMP and vibration will be. The proposed study in this paper will be beneficial for the monitoring and diagnosis of FWISC faults.Keywords
Funding Information
- National Natural Science Foundation of China (51777074, 2017MS151, E2020502032, [2018]-27)
- Fundamental Research Funds for the Central Universities (51777074, 2017MS151, E2020502032, [2018]-27)
- Natural Science Foundation of Hebei Province (51777074, 2017MS151, E2020502032, [2018]-27)
- Top Youth Talent Support Program of Hebei Province (51777074, 2017MS151, E2020502032, [2018]-27)
This publication has 24 references indexed in Scilit:
- Fault diagnosis of rotor winding inter‐turn short circuit for sensorless synchronous generator through screwIET Electric Power Applications, 2017
- Rotor/Stator Inter-Turn Short Circuit Fault Detection for Saturable Wound-Rotor Induction Machine by Modified Magnetic Equivalent Circuit ApproachIEEE Transactions on Magnetics, 2017
- Stator Vibration Characteristic Identification of Turbogenerator among Single and Composite Faults Composed of Static Air-Gap Eccentricity and Rotor Interturn Short CircuitShock and Vibration, 2016
- Discrimination of Synchronous Machines Rotor Faults in Electrical Signature Analysis Based on Symmetrical ComponentsIEEE Transactions on Industry Applications, 2016
- Analysis and Simulation on the Effect of Rotor Interturn Short Circuit on Magnetic Flux Density of Turbo–GeneratorJournal of Electrical Engineering, 2016
- Non-Invasive Detection of Rotor Short-Circuit Fault in Synchronous Machines by Analysis of Stray Magnetic Field and Frame VibrationsIEEE Transactions on Magnetics, 2016
- Theoretical Analysis and Calculation Model of the Electromagnetic Torque of Nonsalient-Pole Synchronous Machines With Interturn Short Circuit in Field WindingsIEEE Transactions on Energy Conversion, 2014
- Diagnosis of Rotor Winding Interturn Short-Circuit in Turbine Generators Using Virtual PowerIEEE Transactions on Energy Conversion, 2014
- A Compositive Diagnosis Method on Turbine-Generator Rotor Winding Inter-turn Short Circuit Fault2006
- The new diagnosis method of rotor winding inter-turn short circuit fault and imbalance fault based on stator and rotor vibration characteristics2005