Bolus arrival time estimation in dynamic contrast-enhanced magnetic resonance imaging of small animals based on spline models
- 1 February 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (4) , 045003
Abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to quantify perfusion and vascular permeability. In most cases a bolus arrival time (BAT) delay exists between the arterial input function (AIF) and the contrast agent arrival in the tissue of interest which needs to be estimated. Existing methods for BAT estimation are tailored to tissue concentration curves, which have a fast upslope to the peak as frequently observed in patient data. However, they may give poor results for curves that do not have this characteristic shape such as tissue concentration curves of small animals. In this paper, we propose a method for BAT estimation of signals that do not have a fast upslope to their peak. The model is based on splines which are able to adapt to a large variety of concentration curves. Furthermore, the method estimates BATs on a continuous time scale. All relevant model parameters are automatically determined by generalized cross validation. We use simulated concentration curves of small animal and patient settings to assess the accuracy and robustness of our approach. The proposed method outperforms a state-of-the-art method for small animal data and it gives competitive results for patient data. Finally, it is tested on in vivo acquired rat data where accuracy of BAT estimation was also improved upon the state-of-the-art method. The results indicate that the proposed method is suitable for accurate BAT estimation of DCE-MRI data, especially for small animals.Keywords
All Related Versions
Funding Information
- Deutsche Forschungsgemeinschaft (KA2679/3-1, KFO 214, GL893/1-1, STO1126/2-1)
This publication has 28 references indexed in Scilit:
- MITK-ModelFit: A generic open-source framework for model fits and their exploration in medical imaging – design, implementation and application on the example of DCE-MRIBMC Bioinformatics, 2019
- Improved Evaluation of Antivascular Cancer Therapy Using Constrained Tracer-Kinetic Modeling for Multiagent Dynamic Contrast-Enhanced MRICancer Research, 2018
- Carbon ion radiotherapy: impact of tumor differentiation on local control in experimental prostate carcinomasRadiation Oncology, 2017
- Precision in measurements of perfusion and microvascular permeability with T1‐weighted dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image seriesMagnetic Resonance in Medicine, 2004
- An automatic approach for estimating bolus arrival time in dynamic contrast MRI using piecewise continuous regression modelsPhysics in Medicine & Biology, 2003
- A Practical Guide to Pseudospectral Methods1996
- Generalized Cross-Validation as a Method for Choosing a Good Ridge ParameterTechnometrics, 1979
- Smoothing noisy data with spline functionsNumerische Mathematik, 1978
- A Practical Guide to Splines1978