Migration of the humeral component of the Souter-Strathclyde elbow prosthesis
- 1 February 2010
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 92-B (2) , 235-241
Abstract
Mechanical loosening which begins with early-onset migration of the prosthesis is the major reason for failure of the Souter-Strathclyde elbow replacement. In a prospective study of 18 Souter-Strathclyde replacements we evaluated the patterns of migration using roentgen stereophotogrammetric analysis. We had previously reported the short-term results after a follow-up of two years which we have now extended to a mean follow-up of 8.2 years (1 to 11.3). Migration was assessed along the co-ordinal axes and overall micromovement was expressed as the maximum total point movement. The alignment of the prosthesis and the presence of radiolucent lines were examined on conventional standardised radiographs. All the humeral components showed increased and variable patterns of migration at the extended follow-up and four humeral components were revised. The maximum total point movement at two years in the revised prostheses was 1.8 mm (sd 1.0) and in the non-revised 0.7 mm (sd 0.5, p = 0.01). Most humeral components migrated into external rotation resulting in an anterior and varus tilt. The ulnar components remained stable.Keywords
This publication has 25 references indexed in Scilit:
- A five-year radiostereometric follow-up of the Birmingham Hip Resurfacing arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2007
- Total elbow replacement with the Souter-Strathclyde prosthesis in rheumatoid arthritisThe Journal of Bone and Joint Surgery. British volume, 2006
- Impaction Grafting in Revision Total Elbow ArthroplastyJournal of Bone and Joint Surgery, 2005
- Limited influence of prosthetic position on aseptic loosening of elbow replacementsActa Orthopaedica, 2005
- Primary Souter-Strathclyde Total Elbow Prosthesis in Rheumatoid ArthritisJournal of Bone and Joint Surgery, 2004
- The kinematic elbow axis as a parameter to evaluate total elbow replacement: A cadaver study of the iBP elbow systemJournal of Shoulder and Elbow Surgery, 2003
- Revisions for aseptic loosening in Souter-Strathclyde elbow arthroplastyActa Orthopaedica, 2002
- The Souter-Strathclyde elbow arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Determination of the optimal elbow axis for evaluation of placement of prosthesesClinical Biomechanics, 1999
- Survivorship and radiological analysis of the standard Souter-Strathclyde total elbow arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1999