Effect of Ambient Temperature and Contact Force on Contact Resistance and Overtemperature Behaviour for Power Engineering Contacts
Authors:
- Volker BehrensVBVolker Behrens
- Edgar SiegleESEdgar Siegle
- Jonas SchreiberJSJonas Schreiber
- Thomas HonigTHThomas Honig
- Michael FinkbeinerMFMichael Finkbeiner
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 66 (10626808) , 1-6
Abstract
With switching devices for power engineering applications the question of overtemperature at steady state current becomes more important as the size of said devices decreases and/or rated currents increase. In order to evaluate the influence of parameters as contact material, contact force, ambient temperature, current and current flow time a PC driven model switch is build up with the ability to set these parameters easily. This paper describes the setup of the model switch and gives first results of tests related to typical conditions of MCCB with a rated current of 160 A. Parameter variations include contact force (5N to 30 N), ambient temperature (25°C to 125°C) and contact material (Ag/C, Ag/Ni, Ag/W, AgNi0,15). Results obtained are discussed on the background of contact surface roughness as well as contact material properties as electrical conductivity and hardness as a function of temperature.Keywords
This publication has 8 references indexed in Scilit:
- Physical Metallurgy2018
- A Multiphysics Finite Element Model of a 35A Automotive Connector Including Multiscale Rough Surface ContactJournal of Electronic Packaging, 2012
- Effects of different loads on the surface of silver metal oxide contacts for general-purpose relaysIEEE Transactions on Components and Packaging Technologies, 2005
- Constriction resistance at high signal frequenciesIEEE Transactions on Components and Packaging Technologies, 2002
- Electrical Contacts1999
- Variations in Contact Resistance Resulting from Oxide Formation and Decomposition in Ag-W and Ag-WC-C Contacts Passing Steady Currents for Long Time PeriodsIEEE Transactions on Components, Hybrids, and Manufacturing Technology, 1986
- Electric Contacts1967
- Constriction resistance and the real area of contactBritish Journal of Applied Physics, 1966