Robust water–fat separation based on deep learning model exploring multi‐echo nature of mGRE
- 24 November 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (5) , 2828-2841
Abstract
Purpose: To design a new deep learning network for fast and accurate water–fat separation by exploring the correlations between multiple echoes in multi‐echo gradient‐recalled echo (mGRE) sequence and evaluate the generalization capabilities of the network for different echo times, field inhomogeneities, and imaging regions.Methods: A new multi‐echo bidirectional convolutional residual network (MEBCRN) was designed to separate water and fat images in a fast and accurate manner for the mGRE data. This new MEBCRN network contains 2 main modules, the first 1 is the feature extraction module, which learns the correlations between consecutive echoes, and the other one is the water–fat separation module that processes the feature information extracted from the feature extraction module. The multi‐layer feature fusion (MLFF) mechanism and residual structure were adopted in the water–fat separation module to increase separation accuracy and robustness. Moreover, we trained the network using in vivo abdomen images and tested it on the abdomen, knee, and wrist images.Results: The results showed that the proposed network could separate water and fat images accurately. The comparison of the proposed network and other deep learning methods shows the advantage in both quantitative metrics and robustness for different TEs, field inhomogeneities, and images acquired for various imaging regions.Conclusion: The proposed network could learn the correlations between consecutive echoes and separate water and fat images effectively. The deep learning method has certain generalization capabilities for TEs and field inhomogeneity. Although the network was trained only in vivo abdomen images, it could be applied for different imaging regions.Keywords
Funding Information
- Chinese Academy of Medical Sciences (YZ201677)
- National Natural Science Foundation of China (11575287, 11705274)
This publication has 40 references indexed in Scilit:
- Fat and water magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- Dixon techniques for water and fat imagingJournal of Magnetic Resonance Imaging, 2008
- Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imagingMagnetic Resonance in Medicine, 2005
- Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithmMagnetic Resonance in Medicine, 2004
- Water Excitation as an Alternative to Fat Saturation in MR Imaging: Preliminary Results in Musculoskeletal ImagingRadiology, 2002
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Multisection fat-water imaging with chemical shift selective presaturation.Radiology, 1987
- Comparative Efficiency of Different Pulse Sequences in MR ImagingJournal of Computer Assisted Tomography, 1986
- MR ImagingJournal of Computer Assisted Tomography, 1985
- Simple proton spectroscopic imaging.Radiology, 1984