Flow Patterns at Stented Coronary Bifurcations
- 1 August 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 5 (4) , 530-539
Abstract
Background—: The ideal bifurcation stenting technique is not established, and data on the hemodynamic characteristics at stented bifurcations are limited. Methods and Results—: We used computational fluid dynamics analysis to assess hemodynamic parameters known affect the risk of restenosis and thrombosis at coronary bifurcations after the use of various single- and double-stenting techniques. We assessed the distributions and surface integrals of the time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (t r ). Single main branch stenting without side branch balloon angioplasty or stenting provided the most favorable hemodynamic results (integrated values of TAWSS=4.13·10 −4 N, OSI=7.52·10 −6 m 2 , t r =5.57·10 −4 m 2 /Pa) with bifurcational area subjected to OSI values >0.25, >0.35, and >0.45 calculated as 0.36 mm 2 , 0.04 mm 2 , and 0 mm 2 , respectively. Extended bifurcation areas subjected to these OSI values were seen after T-stenting: 0.61 mm 2 , 0.18 mm 2 , and 0.02 mm 2 , respectively. Among the considered double-stenting techniques, crush stenting (integrated values of TAWSS=1.18·10 −4 N, OSI=7.75·10 −6 m 2 , t r =6.16·10 −4 m 2 /Pa) gave the most favorable results compared with T-stenting (TAWSS=0.78·10 −4 N, OSI=10.40·10 −6 m 2 , t r =6.87·10 −4 m 2 /Pa) or the culotte technique (TAWSS=1.30· 10 −4 N, OSI=9.87·10 −6 m 2 , t r =8.78·10 −4 m 2 /Pa). Conclusions—: In the studied models of computer simulations, stenting of the main branch with our without balloon angioplasty of the side branch offers hemodynamic advantages over double stenting. When double stenting is considered, the crush technique with the use of a thin-strut stent may result in improved immediate hemodynamics compared with culotte or T-stenting.Keywords
This publication has 32 references indexed in Scilit:
- Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug CoatingsCirculation, 2011
- Bioresorbable ScaffoldCirculation, 2011
- Vascular response to a third generation everolimus-eluting stentEuroIntervention, 2010
- Pathological Findings at Bifurcation LesionsJACC, 2010
- Vortex formation and recirculation zones in left anterior descending artery stenoses: computational fluid dynamics analysisPhysics in Medicine & Biology, 2010
- Simulation of cardiac motion on non-Newtonian, pulsating flow development in the human left anterior descending coronary arteryPhysics in Medicine & Biology, 2008
- Time-dependent 3D simulations of the hemodynamics in a stented coronary arteryBiomedical Materials, 2007
- Predictors of restenosis after treatment of bifurcational lesions with paclitaxel eluting stents: A multicenter prospective registry of 150 consecutive patientsCatheterization and Cardiovascular Interventions, 2006
- Pulsatile Flow in the Human Left Coronary Artery Bifurcation: Average ConditionsJournal of Biomechanical Engineering, 1996
- Pulsatile Flow Visualization in the Abdominal Aorta Under Differing Physiologic Conditions: Implications for Increased Susceptibility to AtherosclerosisJournal of Biomechanical Engineering, 1992