Sensitivity of CFD Based Hemodynamic Results in Rabbit Aneurysm Models to Idealizations in Surrounding Vasculature
- 26 August 2010
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 132 (9) , 091009
Abstract
Computational fluid dynamics (CFD) studies provide a valuable tool for evaluating the role of hemodynamics in vascular diseases such as cerebral aneurysms and atherosclerosis. However, such models necessarily only include isolated segments of the vasculature. In this work, we evaluate the influence of geometric approximations in vascular anatomy on hemodynamics in elastase induced saccular aneurysms in rabbits. One representative high aspect ratio (AR—height/neck width) aneurysm and one low AR aneurysm were created at the origin of the right common carotid artery in two New Zealand white rabbits. Three-dimensional (3D) reconstructions of the aneurysm and surrounding arteries were created using 3D rotational angiographic data. Five models with varying extents of neighboring vasculature were created for both the high and low AR cases. A reference model included the aneurysm sac, left common carotid artery (LCCA), aortic arch, and downstream trifurcation/quadrification. Three-dimensional, pulsatile CFD studies were performed and streamlines, wall shear stress (WSS), oscillatory shear index, and cross sectional velocity were compared between the models. The influence of the vascular domain on intra-aneurysmal hemodynamics varied between the low and high AR cases. For the high AR case, even a simple model including only the aneurysm, a small section of neighboring vasculature, and simple extensions captured the main features of the steamline and WSS distribution predicted by the reference model. However, the WSS distribution in the low AR case was more strongly influenced by the extent of vasculature. In particular, it was necessary to include the downstream quadrification and upstream LCCA to obtain good predictions of WSS. The findings in this work demonstrate the accuracy of CFD results can be compromised if insufficient neighboring vessels are included in studies of hemodynamics in elastase induced rabbit aneurysms. Consideration of aspect ratio, hemodynamic parameters of interest, and acceptable magnitude of error when selecting the vascular domain will increase reliability of the results while decreasing computational time.Keywords
This publication has 47 references indexed in Scilit:
- An Original Flow Diversion Device for the Treatment of Intracranial AneurysmsStroke, 2009
- A Parametric Model for Studies of Flow in Arterial BifurcationsAnnals of Biomedical Engineering, 2008
- Gene Expression Profiling of Experimental Saccular Aneurysms Using Deoxyribonucleic Acid Microarrays: Fig 1.American Journal of Neuroradiology, 2008
- Complex Hemodynamics at the Apex of an Arterial Bifurcation Induces Vascular Remodeling Resembling Cerebral Aneurysm InitiationStroke, 2007
- A MODEL SYSTEM FOR MAPPING VASCULAR RESPONSES TO COMPLEX HEMODYNAMICS AT ARTERIAL BIFURCATIONS IN VIVONeurosurgery, 2006
- The aspect ratio (dome/neck) of ruptured and unruptured aneurysmsJournal of Neurosurgery, 2003
- Cerebral Aneurysms Arising at Nonbranching SitesStroke, 1997
- ARTIFICIAL BOUNDARIES AND FLUX AND PRESSURE CONDITIONS FOR THE INCOMPRESSIBLE NAVIER-STOKES EQUATIONSInternational Journal for Numerical Methods in Fluids, 1996
- Cerebral aneurysms and variations in the circle of Willis.Stroke, 1984
- A model study of why some intracranial aneurysms thrombose but others rupture.Stroke, 1978