Design limitations of using magnetic inductive coupling to verify nasogastric tube placement
Authors:
- 26 March 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Abstract
Nasogastric tube insertion is a standard procedure but with potentially fatal consequences if misplaced. Many bedside methods have been proposed for identifying misplacement including magnetic inductive coupling. This study aims to identify the coil design limitations for nasogastric tube placement confirmation using magnetic inductive coupling. The fundamental limits on the coil sizes and detection distances are identified based on the anatomical understanding. Candidate designs are simulated and fabricated, and key parameters such as coil radius and penetration depth are examined. Specifically, the mutual inductance and coupling factor between the coils in the candidate designs are both calculated and measured with respected to distance. This work highlights that a small coil of up to 3 mm in diameter could be integrated into a nasogastric tube without impairing clinical function. These preliminary results suggest that magnetic inductive coupling is a promising approach for nasogastric tube localisation, however, optimisation of the detector coil size could improve localisation performance.Keywords
Funding Information
- European Research Council
This publication has 13 references indexed in Scilit:
- Pediatric Nasogastric Tube Placement and Verification: Best Practice Recommendations From the NOVEL ProjectNutrition in Clinical Practice, 2018
- Study to determine the likely accuracy of pH testing to confirm nasogastric tube placementBMJ Open Gastroenterology, 2018
- 4-coils magnetic resonance coupling wireless power transfer with varying rotational angle2018
- Down the wrong road – a case report of inadvertent nasogastric tube insertion leading to lung laceration and important pearls to avoid complicationsQatar Medical Journal, 2017
- Nasogastric tube placement confirmation: where we are and where we should be headingProceedings of Singapore Healthcare, 2017
- Impedance matching control method for an underwater magnetic resonance-based wireless power transfer system with metamaterialsJournal of Electromagnetic Waves and Applications, 2016
- Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric TubeCase Reports in Critical Care, 2015
- An Overview of Technical Challenges and Advances of Inductive Wireless Power TransmissionProceedings of the IEEE, 2013
- Evaluation of Wireless Resonant Power Transfer Systems With Human Electromagnetic Exposure LimitsIEEE Transactions on Electromagnetic Compatibility, 2012
- Checking placement of nasogastric feeding tubes in adults (interpretation of x ray images): summary of a safety report from the National Patient Safety AgencyBMJ, 2011