Robust Room Impulse Response Measurement Using Perfect Periodic Sequences for Wiener Nonlinear Filters
Open Access
- 29 October 2020
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 9 (11) , 1793
Abstract
The paper discusses a measurement approach for the room impulse response (RIR), which is insensitive to the nonlinearities that affect the measurement instruments. The approach employs as measurement signals the perfect periodic sequences for Wiener nonlinear (WN) filters. Perfect periodic sequences (PPSs) are periodic sequences that guarantee the perfect orthogonality of a filter basis functions over a period. The PPSs for WN filters are appealing for RIR measurement, since their sample distribution is almost Gaussian and provides a low excitation to the highest amplitudes. RIR measurement using PPSs for WN filters is studied and its advantages and limitations are discussed. The derivation of PPSs for WN filters suitable for RIR measurement is detailed. Limitations in the identification given by the underestimation of RIR memory, order of nonlinearity, and effect of measurement noise are analysed and estimated. Finally, experimental results, which involve both simulations using signals affected by real nonlinear devices and real RIR measurements in the presence of nonlinearities, compare the proposed approach with the ones that are based on PPSs for Legendre nonlinear filter, maximal length sequences, and exponential sweeps.Keywords
This publication has 31 references indexed in Scilit:
- Perfect periodic sequences for even mirror Fourier nonlinear filtersSignal Processing, 2014
- Fourier nonlinear filtersSignal Processing, 2014
- On the effects of nonlinearities in room impulse response measurements with exponential sweepsApplied Acoustics, 2012
- Multi‐Channel System Identification with Perfect Sequences – Theory and Applications –2008
- Low-complexity nonlinear adaptive filters for acoustic echo cancellation in GSM handset receiversEuropean Transactions on Telecommunications, 2003
- Broadband versus stepped sine FRF measurementsIEEE Transactions on Instrumentation and Measurement, 2000
- An optimum computer-generated pulse signal suitable for the measurement of very long impulse responsesThe Journal of the Acoustical Society of America, 1995
- Computer-generated pulse signal applied for sound measurementThe Journal of the Acoustical Society of America, 1981
- Integrated-impulse method measuring sound decay without using impulsesThe Journal of the Acoustical Society of America, 1979
- Subharmonics in Forced Oscillations in Dissipative Systems. Part IThe Journal of the Acoustical Society of America, 1935