Reliability and measurement error of the BioTonix Video Posture Evaluation System— Part I: Inanimate objects
- 1 May 2002
- journal article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 25 (4) , 246-250
Abstract
To investigate the reliability, concurrent validity, and error of a new video digitizing system for evaluating posture when applied to inanimate objects. Delayed repeated measures of digital images of inanimate objects. University laboratory. Digital video images of inanimate objects (5 parallelograms) of different sizes and shapes were obtained with the BioTonix postural evaluation system. Three examiners digitized video images of inanimate objects twice; the second data collection was 1 week after the first set. The objects were digitized with both high- and low-resolution settings of the video screen. The Tonix's measurements were statistically compared with the actual object dimensions. Statistical evaluations of reliability and validity were conducted. For distances, both intraclass and interclass correlation coefficients were very high, 0.99 for the estimate. The low- versus high-resolution settings were comparable for distances. For angles, on the low-resolution setting, both intraclass and interclass correlation coefficients were very high: 0.969 and 0.953. On the high-resolution setting, for angles, both intraclass and interclass coefficients were well above 0.99. The difference of the actual size and the means of the digitized measurements of the means were small: at most 1.5 degrees for angles and 3.3 mm for distances. The standard deviations were small, and the confidence intervals were narrow. Our results demonstrate that the BioTonix's video system has high degrees of reliability and validity. Thus this system would seem suitable for clinical use in the analysis of posture.Keywords
This publication has 32 references indexed in Scilit:
- Inter-rater reliability of postural observation after strokeClinical Rehabilitation, 1999
- Evaluation of interrater reliability for posture observations in a field studyApplied Ergonomics, 1999
- Kinematic characteristics of standing disequilibrium: Reliability and validity of a posturographic protocolArchives of Physical Medicine and Rehabilitation, 1999
- Bone position estimation from skin marker co-ordinates using global optimisation with joint constraintsJournal of Biomechanics, 1999
- Are Performance-Based Measures Sufficiently Reliable for Use in Multicenter Trials?The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 1999
- The Reliability and Validity of a Chair Sit-and-Reach Test as a Measure of Hamstring Flexibility in Older AdultsResearch Quarterly for Exercise and Sport, 1998
- Validation of Portable Ergonomic Observation (PEO) method using optoelectronic and video recordingsApplied Ergonomics, 1997
- Reducing random measurement error in assessing postural load on the back in epidemiologic surveysScandinavian Journal of Work, Environment & Health, 1995
- Incidence of Common Postural Abnormalities in the Cervical, Shoulder, and Thoracic Regions and Their Association with Pain in Two Age Groups of Healthy SubjectsPhysical Therapy, 1992
- Preliminary Investigation of the Reliability and Validity of a Tool for the Assessment of Body Position and Motor ActivityNursing Research, 1976