In vivo biological safety evaluation of an iron-based bioresorbable drug-eluting stent
- 15 September 2020
- journal article
- research article
- Published by Springer Nature in BioMetals
- Vol. 33 (4-5) , 217-228
Abstract
Bioresorbable stents (BRS) are investigated and designed to revascularize occluded arteries. The iron-based bioresorbable stent is a promising device in interventional therapies, although it’s corrosion and bioresorption rate remain challenging. In this work, we introduced a novel nitrided iron coronary stent (IBS) with enhanced degradation rate compared with pure iron stent. To evaluate the biosafety of this device, a sub-chronic systemic toxicity study was conducted and a stainless steel stent (Supporter™) served as a control. Here, the bioresorbable stent was first evaluated in rat abdominal aortic implantation model. When subjected to exaggerated exposure dose, no clinical signs of toxicity or mortality were observed in either, the IBS group or the control group. Histopathological examinations showed the corrosion particles of iron were encapsulated by fibrocytes and engulfed by macrophages, indicating that the degradation of iron was in the early stage. Our results demonstrated that the nitrided iron stent did not induce systemic toxicity under the experimental conditions.Keywords
Funding Information
- National Key R&D Program of China (2017YFC1105003)
This publication has 26 references indexed in Scilit:
- Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradationMaterials Science and Engineering: C, 2018
- 2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudyThe Lancet, 2017
- Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trialThe Lancet, 2016
- Characterization and in vivo evaluation of a bio-corrodible nitrided iron stentJournal of Materials Science: Materials in Medicine, 2012
- Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆Acta Biomaterialia, 2010
- A Biodegradable Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Peripheral Vascular Application: Preliminary Experience in the PigJournal of Endovascular Therapy, 2007
- A Biodegradable Slotted Tube Stent Based on Poly(l-lactide) and Poly(4-hydroxybutyrate) for Rapid Balloon-ExpansionAnnals of Biomedical Engineering, 2007
- Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trialThe Lancet, 2007
- Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort studyThe Lancet, 2007
- Morphological Predictors of Restenosis After Coronary Stenting in HumansCirculation, 2002